{"title":"Hanna Instruments","description":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eWorld's leading brand in pH measurement and analysis, pioneers in the design and development.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"multiparameter-ph-ec-tds-probe-hi1285-5","title":"Multiparameter pH\/EC\/TDS probe, HI1285-5","description":"\u003cp\u003eThe HI1285-5 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC\/TDS, and temperature within a single polypropylene body.\u003c\/p\u003e\u003cp\u003eTemperature sensor, cloth junction, gel-filled, 7-pole; 2m cable, for greenhouses, hydroponics, environmental monitoring, water treatment, boilers and cooling towers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003epH\/EC\/TDS Multiparameter Probe - HI1285-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003esingle, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003ecloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003egel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003epolypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eGlass Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003eLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003espheric (8mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eMatching Pin\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003e0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003e0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003e95mm \/ 185mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003e16mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003e7-pole; 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003eDIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eRecommended Use\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.595%;\"\u003eGreenhouses, hydroponics, environmental monitoring, water treatment, boilers, cooling towers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eSuitable for the following Hanna meters:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHI9811-5: pH, conductivity to 6000µS\/cm and temperature with a water-resistant meter\u003c\/li\u003e\n\u003cli\u003eHI9812-5: versatile instruments for water conditioning\u003c\/li\u003e\n\u003cli\u003eHI9813-5: waterproof pH\/EC\/TDS\/temperature meter for growers\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42663940948158,"sku":"EHIE1285-5","price":321.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI1285-5.jpg?v=1757382194"},{"product_id":"multi-pin-ph-electrode-for-hi-9813-6","title":"Multi-pin pH electrode, HI9813-6 multiparameter meter","description":"\u003cp\u003eThe HI1285-6 is a 3-in-1 pre-amplified multiparameter probe with CAL Check that measures pH, EC\/TDS, and temperature within a single polypropylene body. Using this probe allows users to employ the CAL Check feature of the HI9813-6 portable multiparameter meter. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC\/TDS portion of this probe utilises two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC\/TDS readings are compensated for temperature variations in both standards and samples.\u003cbr\u003e\u003cbr\u003eThe design consideration for the HI1285-6 is ideal for measuring the pH, EC\/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers. The HI1285-6 is designed for use with Hanna's HI9813-6 portable multiparameter meter.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePre-amplified pH Electrode\u003c\/li\u003e\n\u003cli\u003eAmperometric EC\/TDS Sensor\u003c\/li\u003e\n\u003cli\u003eCAL Check Compatible\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003epH\/EC\/TDS Multiparameter Probe with CAL Check - HI1285-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003esingle, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003ecloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003egel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003epolypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eGlass Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003espheric (8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eMatching Pin\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e95mm \/ 185mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e16mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e7-pole; 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eDIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eRecommended Use\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eGreenhouses, hydroponics, environmental monitoring, water treatment, boilers, cooling towers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eNotes\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eTo be used with HI9813-6 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42663941046462,"sku":"EHIE1285-6","price":321.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/Ehie1285-6.jpg?v=1757382197"},{"product_id":"ph-ec-tds-c-tester","title":"pH\/EC\/TDS\/C testers","description":"\u003cp\u003eThese combination waterproof testers offer high accuracy pH, EC\/ TDS and temperature measurements in a single instrument. \u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eHI98129\u003c\/strong\u003e makes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, low range EC\/TDS (0 to 3999µS\/cm EC\/ 0 to 2000ppm TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eWaterproof\u003c\/li\u003e\n\u003cli\u003eReplaceable pH electrode with extractable junction\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/proscitech.com.au\/products\/replacement-electrode-for-hi98127-to-hi98130\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eReplacement electrode available\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe \u003cstrong\u003eHI98130 \u003c\/strong\u003emakes measuring pH quick and easy! This lightweight, waterproof tester offers high accuracy pH, high range EC\/TDS (0.00 to 20.00mS\/cm EC\/ 0.00 to 10.00ppt TDS) and temperature measurements in a single handheld unit! No more switching between meters for your routine measurements. Great for hydroponics, aquariums, pools, \u0026amp; ponds.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eWide range of 0.00 to 14.00pH\u003c\/li\u003e\n\u003cli\u003eReplaceable pH electrode with extractable junction\u003c\/li\u003e\n\u003cli\u003eSelectable EC to TDS conversion factor of either a 0.45 or 1.0β (BETA)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003eHI98129\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003eHI98130\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003eCombo pH\/Conductivity\/TDS Tester (Low Range)\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003eCombo pH\/Conductivity\/TDS Tester (High Range)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003epH Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003epH Calibration\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eEC Range\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003e0.00 to 20.00 mS\/cm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eEC Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003e1 µS\/cm\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003e0.01 mS\/cm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003e±2% F.S.\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003e±2% F.S.\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eEC Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003eautomatic, one-point at: 1413µS\/cm\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003eautomatic, one-point at: 12.88mS\/cm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003e0 to 2000ppm (mg\/L)\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003e0.00 to 10.00 ppt (g\/L)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003e1ppm (mg\/L)\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003e0.01 ppt (g\/L)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003e±2% F.S.\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003e±2% F.S.\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 36.3749%; text-align: center;\"\u003eautomatic, one-point at: 1382ppm (mg\/L)\u003c\/td\u003e\n\u003ctd style=\"width: 39.0655%; text-align: center;\"\u003eautomatic, one-point at: 6.44ppt (g\/L)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003eautomatic with β adjustable from 0.0 to 2.4% \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e0.0 to 60.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003epH Electrode\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003eHI73127 (replaceable; included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e1.5V (4) \/ approx. 100 hours of continuous use, auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e0 to 50°C; RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e163 x 40 x 26mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.8915%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 75.9502%; text-align: center;\"\u003e100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eAccessories:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEHIE1285-6\u003c\/strong\u003e is a multi-pin pH electrode for HI9813-6, with cloth junction, 7-pole, 2m cable, for greenhouses, hydroponics, environmental monitoring, water treatment, boilers and cooling towers. HI9813-6 is a waterproof pH\/EC\/TDS\/°C meter with pH electrode diagnostics.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Low range EC \/ Each","offer_id":42663955988670,"sku":"EHI98129","price":361.55,"currency_code":"AUD","in_stock":true},{"title":"High range EC \/ Each","offer_id":42663956021438,"sku":"EHI98130","price":405.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/Ehi98130__2.jpg?v=1757382200"},{"product_id":"phep-ph-celsius-tester-waterproof","title":"pHep pH\/temperature testers, waterproof","description":"\u003cp\u003eHanna's \u003cstrong\u003epHep4\u003c\/strong\u003e waterproof tester is an advanced meter has many features that can be found in portable and benchtop meters.  This ergonomic meter measures from -2.0 to 16.0 pH with an accuracy of ±0.1 pH. pHep4 features automatic one or two-point calibration and automatic temperature compensation. The large multi level LCD display shows both pH and temperature readings simultaneously, while a stability indicator is displayed to alert the user when a stable reading has been obtained. The pHep4 tester also features a replaceable pH probe that has a unique extendable cloth junction to clear any clogging that occurs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eWaterproof\u003c\/li\u003e\n\u003cli\u003eReplaceable pH Electrode \u003c\/li\u003e\n\u003cli\u003eAutomatic Two-Point pH Calibration\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/proscitech.com.au\/products\/replacement-electrode-for-hi98127-to-hi98130\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eReplacement electrode available\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHanna's \u003cstrong\u003epHep5\u003c\/strong\u003e is an advanced, ergonomic, waterproof pH and temperature tester, with  0.01 resolution, that measures from -2.0 to 16.0 pH  pH and accuracy of ±0.05 pH. pHep5 features automatic one or two-point calibration to known buffer and automatic temperature compensation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"width: 34.2514%; text-align: center;\"\u003eHI98127\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; text-align: center;\"\u003eHI98128\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"width: 34.2514%; text-align: center;\"\u003epHep4 pH\/Temperature Tester\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; text-align: center;\"\u003eWaterproof pHep5 pH\/Temperature Tester\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003epH Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003e-2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 34.2514%; text-align: center;\"\u003e0.1 pH\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; text-align: center;\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 34.2514%; text-align: center;\"\u003e±0.1 pH\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; text-align: center;\"\u003e±0.05 pH\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003epH Calibration\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003e-5.0 to 60.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003epH Electrode\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003eHI73127 replaceable pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd style=\"width: 34.2514%; text-align: center;\"\u003eintegrated thermistor\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; text-align: center;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003eafter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003e1.5V (4) \/ approx. 300 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003e-5 to 50°C; RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003e163 x 40 x 26mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9996%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 67.8421%; text-align: center;\"\u003e100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"pHep 4 \/ Each","offer_id":42663984234686,"sku":"EHI98127","price":261.0,"currency_code":"AUD","in_stock":true},{"title":"pHep 5 \/ Each","offer_id":42663984267454,"sku":"EHI98128","price":287.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/Ehi98127.jpg?v=1757382202"},{"product_id":"laboratory-research-grade-benchtop-ph-mv-and-ec-tds-salinity-resistivity-meter","title":"Research grade multi-parameter benchtop meter, HI5521","description":"\u003cp\u003eThe HI5521 is an advanced research grade benchtop pH\/mV\/EC\/TDS\/Salinity\/Resistivity meter that is completely customisable with a large colour LCD, capacitive touch keys, and USB port for computer connectivity. The HI5521 is rich in features including data logging, alarm limits, comprehensive GLP, and many more while retaining simplicity in use with both dedicated key for routine operation and virtual keys that guide the user through setup options. The HI5521 ensures confidence in pH measurements with the exclusive Hanna Instruments CAL Check feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCapacitive touch keypad\u003c\/li\u003e\n\u003cli\u003eTwo independent channels\u003c\/li\u003e\n\u003cli\u003eCAL Check Probe Diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd data-th=\"Product Name\" style=\"text-align: center;\"\u003eProfessional benchtop pH\/EC meter with 5.5\" colour LCD and capacitive touch keypad. Fully customisable, auto-logging, real-time graphic, auto-end point mode, CAL Check™, USP, USB, 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003epH Range\u003c\/th\u003e\n\u003ctd data-th=\"pH Range\" style=\"text-align: center;\"\u003e-2.0 to 20.0 pH \/ -2.00 to 20.00 pH \/ -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003epH Resolution\u003c\/th\u003e\n\u003ctd data-th=\"pH Resolution\" style=\"text-align: center;\"\u003e0.1 pH \/ 0.01 pH \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003epH Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"pH Accuracy\" style=\"text-align: center;\"\u003e±0.1 pH \/ ±0.01 pH \/ ±0.002 pH ± 1LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003epH Calibration\u003c\/th\u003e\n\u003ctd data-th=\"pH Calibration\" style=\"text-align: center;\"\u003eUp to five-point calibration, eight standard buffers available (pH 1.68, 3.00, 4.01, 6.86, 7.01,9.18, 10.01, 12.45), and five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003epH Temperature Compensation\u003c\/th\u003e\n\u003ctd data-th=\"pH Temperature Compensation\" style=\"text-align: center;\"\u003eautomatic or manual from -20.0 to 120.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003emV Range\u003c\/th\u003e\n\u003ctd data-th=\"mV Range\" style=\"text-align: center;\"\u003e±2000.0mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003emV Resolution\u003c\/th\u003e\n\u003ctd data-th=\"mV Resolution\" style=\"text-align: center;\"\u003e0.1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003emV Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"mV Accuracy\" style=\"text-align: center;\"\u003e±0.2mV ± 1LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003emV Relative Offset\u003c\/th\u003e\n\u003ctd data-th=\"mV Relative Offset\" style=\"text-align: center;\"\u003e±2000.0mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC Range\u003c\/th\u003e\n\u003ctd data-th=\"EC Range\" style=\"text-align: center;\"\u003e0.000 to 9.999µS\/cm, 10.00 to 99.99µS\/cm, 100.0 to 999.9µS\/cm, 1.000 to 9.999mS\/cm, 10.00 to 99.99mS\/cm, 100.0 to 1000.0mS\/cm actual EC*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC Resolution\u003c\/th\u003e\n\u003ctd data-th=\"EC Resolution\" style=\"text-align: center;\"\u003e0.001µS\/cm, 0.01µS\/cm, 0.1µS\/cm, 1µS\/cm, 0.001mS\/cm, 0.01mS\/cm, 0.1mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"EC Accuracy\" style=\"text-align: center;\"\u003e±1% of reading (±0.01µS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC Calibration\u003c\/th\u003e\n\u003ctd data-th=\"EC Calibration\" style=\"text-align: center;\"\u003eautomatic standard recognition (0.000µS\/cm, 84.00µS\/cm, 1.413mS\/cm, 5.000mS\/cm, 12.88mS\/cm, 80.00mS\/cm, 111.8mS\/cm) or user standard; single point or multi-point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTDS Range\u003c\/th\u003e\n\u003ctd data-th=\"TDS Range\" style=\"text-align: center;\"\u003e0.000 to 9.999ppm, 10.00 to 99.99ppm, 100.0 to 999.9ppm, 1.000 to 9.999ppt, 10.00 to 99.99ppt, 100.0 to 400.0ppt actual TDS* (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTDS Resolution\u003c\/th\u003e\n\u003ctd data-th=\"TDS Resolution\" style=\"text-align: center;\"\u003e0.001ppm, 0.01ppm, 0.1ppm, 1ppm, 0.001ppt, 0.01ppt, 0.1ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTDS Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"TDS Accuracy\" style=\"text-align: center;\"\u003e±1% of reading (±0.01ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC\/TDS Temperature Compensation\u003c\/th\u003e\n\u003ctd data-th=\"EC\/TDS Temperature Compensation\" style=\"text-align: center;\"\u003edisabled, linear and non-linear (natural water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Correction Coefficient\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Correction Coefficient\" style=\"text-align: center;\"\u003e0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference Temperature\u003c\/th\u003e\n\u003ctd data-th=\"Reference Temperature\" style=\"text-align: center;\"\u003e5.0 to 30.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCell Constant\u003c\/th\u003e\n\u003ctd data-th=\"Cell Constant\" style=\"text-align: center;\"\u003e0.0500 to 200.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCell Type\u003c\/th\u003e\n\u003ctd data-th=\"Cell Type\" style=\"text-align: center;\"\u003e4 cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity (% NaCl) Range\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (% NaCl) Range\" style=\"text-align: center;\"\u003e0.0 to 400.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity (% NaCl) Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (% NaCl) Resolution\" style=\"text-align: center;\"\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity (% NaCl) Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (% NaCl) Accuracy\" style=\"text-align: center;\"\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity (PSU) Range\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Range\" style=\"text-align: center;\"\u003e0.00 to 42.00psu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity (PSU) Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Resolution\" style=\"text-align: center;\"\u003e0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity (PSU) Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Accuracy\" style=\"text-align: center;\"\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity (PSU) Calibration\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Calibration\" style=\"text-align: center;\"\u003e1 point (with HI7037 standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity Range\u003c\/th\u003e\n\u003ctd data-th=\"Salinity Range\" style=\"text-align: center;\"\u003e0.00 to 80.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Salinity Resolution (ppt)\" style=\"text-align: center;\"\u003e0.01ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Salinity Accuracy (ppt)\" style=\"text-align: center;\"\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResistivity Range\u003c\/th\u003e\n\u003ctd data-th=\"Resistivity Range\" style=\"text-align: center;\"\u003e1.0 to 99.9 Ω-cm; 100 to 999 Ω-cm; 1.00 to 9.99 KΩ-cm; 10.0 to 99.9 KΩ-cm; 100 to 999 KΩ-cm; 1.00 to 9.99 MΩ-cm; 10.0 to 100.0 MΩ-cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResistivity Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Resistivity Resolution\" style=\"text-align: center;\"\u003e0.1 Ω-cm; 1 Ω-cm; 0.01 KΩ-cm; 0.1 KΩ-cm; 1 KΩ-cm; 0.01 MΩ-cm; 0.1 MΩ-cm*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResistivity Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Resistivity Accuracy\" style=\"text-align: center;\"\u003e±2% of reading (±1 Ω-cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Range\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Range\" style=\"text-align: center;\"\u003e-20.0 to 120.0°C**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Resolution\" style=\"text-align: center;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Accuracy\" style=\"text-align: center;\"\u003e±0.2°C (without probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput Channels\u003c\/th\u003e\n\u003ctd data-th=\"Input Channels\" style=\"text-align: center;\"\u003e2 (pH\/mV; Conductivity\/Resistivity\/ TDS\/Salinity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003epH Electrode\u003c\/th\u003e\n\u003ctd data-th=\"pH Electrode\" style=\"text-align: center;\"\u003eHI1131B glass body pH electrode with BNC connector and 1m cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC\/TDS Probe\u003c\/th\u003e\n\u003ctd data-th=\"EC\/TDS Probe\" style=\"text-align: center;\"\u003eHI76312 platinum, four-ring EC\/TDS probe with and 1m cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Probe\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Probe\" style=\"text-align: center;\"\u003eHI7662-T stainless steel temperature probe with 1m cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLogging Type\u003c\/th\u003e\n\u003ctd data-th=\"Logging Type\" style=\"text-align: center;\"\u003eAutomatic, Manual, AutoHold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLogging Memory\u003c\/th\u003e\n\u003ctd data-th=\"Logging Memory\" style=\"text-align: center;\"\u003eUp to 100 lots, 50,000 records max\/lot; maximum 100,000 data points \/ channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLogging Interval\u003c\/th\u003e\n\u003ctd data-th=\"Logging Interval\" style=\"text-align: center;\"\u003e14 selectable between 1 second and 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd data-th=\"Connectivity\" style=\"text-align: center;\"\u003eOpto-isolated USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGLP\u003c\/th\u003e\n\u003ctd data-th=\"GLP\" style=\"text-align: center;\"\u003eyes (GLP Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCalibration Timeout Reminder\u003c\/th\u003e\n\u003ctd data-th=\"Calibration Timeout Reminder\" style=\"text-align: center;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUSP Compliant\u003c\/th\u003e\n\u003ctd data-th=\"USP Compliant\" style=\"text-align: center;\"\u003eUSP \u0026lt;645\u0026gt; Application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProfiles\u003c\/th\u003e\n\u003ctd data-th=\"Profiles\" style=\"text-align: center;\"\u003eup to 10, 5 each channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd data-th=\"Display\" style=\"text-align: center;\"\u003eColor Graphic LCD 240 x 320 pixels, 8 keys capacitive touch keyboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd data-th=\"Power Supply\" style=\"text-align: center;\"\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd data-th=\"Environment\" style=\"text-align: center;\"\u003e0 to 50°C, RH max 95% non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" style=\"text-align: center;\"\u003e160 x 231 x 94mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd data-th=\"Weight\" style=\"text-align: center;\"\u003e1.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664106885310,"sku":"HI5521-02","price":2220.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/hi5521.jpg?v=1757382207"},{"product_id":"ph-calibration-buffer-ph6-86-500ml","title":"Electrode calibration solution, pH 6.86","description":"\u003cp\u003eHI7006L is a premium quality pH 6.86 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAir tight bottle with tamper-proof seal to ensure quality and freshness of solution\u003c\/li\u003e\n\u003cli\u003eEach bottle marked with lot number and expiration date. Hanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\n\u003cli\u003eColour coded label for easy pH buffer value identification for different buffer values\u003c\/li\u003e\n\u003cli\u003eSolution does not contain any dyes that may stain the reference cell of a pH electrode\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"margin-right: calc(0%); width: 100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003eDescription\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003estandard calibration buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003eCertificate of Analysis\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003epH Accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003epH Value @ 25°C\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003e6.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003ePackage\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003ebottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664107114686,"sku":"HI7006L","price":45.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI7006.jpg?v=1767318027"},{"product_id":"standard-calibration-solution-9-18-ph-500ml","title":"Electrode calibration solution, pH 9.18","description":"\u003cp\u003eHI7009L is a premium quality pH 9.18 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664107311294,"sku":"HI7009L","price":45.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/hi7009l__1.jpg?v=1757382211"},{"product_id":"electrode-storage-solution-1","title":"Hanna electrode storage solution","description":"\u003cp\u003eA storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionised water. The Hanna Instruments storage solution is specifically formulated to minimise microbial growth and to prevent any effects of diffusion\/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and\/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSpecial formulation to minimise microbial growth and osmotic\/diffusion effects between the solution and inner reference electrolyte\u003c\/li\u003e\n\u003cli\u003eManufactured specifically for pH and ORP electrodes\u003c\/li\u003e\n\u003cli\u003eClearly marked expiration date and lot number\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"30ml","offer_id":43291058503870,"sku":"HI70300S","price":33.0,"currency_code":"AUD","in_stock":true},{"title":"500ml","offer_id":42664107507902,"sku":"HI70300L","price":53.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI70300.jpg?v=1780546448"},{"product_id":"zero-oxygen-solution-500ml","title":"Zero oxygen solution","description":"\u003cp\u003eHI7040L is a high quality, bicomponent zero oxygen solution made from reagent grade chemicals. Hanna dissolved oxygen solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.  Prepared with reagent grade chemicals. Hassle-free, easy to mix chemical component bottles.  Air-tight seal to ensure the quality of the solution. \u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664107540670,"sku":"HI7040L","price":66.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI7040L.jpg?v=1757382215"},{"product_id":"electrode-cleaning-solution-general-purpose","title":"Electrode cleaning solution","description":"\u003cp\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardisation curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60mV. The deviation from 0mV is not unusual but ideally should be no greater than ±30mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.\u003c\/p\u003e\u003cp\u003e \u003cimg title=\"cleaning solution\" src=\"https:\/\/hannainst.com.au\/media\/wysiwyg\/products\/solutions\/Screen_Shot_2015-01-08_at_3.20.38_PM.png\" alt=\"\"\u003eCleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI7061L cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.  \u003c\/p\u003e\u003cp dir=\"ltr\"\u003eAir tight bottle with tamper-proof seal\u003c\/p\u003e\u003cul\u003e\u003cli dir=\"ltr\"\u003e\u003cp dir=\"ltr\"\u003eEnsures quality and freshness of solution\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp dir=\"ltr\"\u003eEach bottle marked with lot number and expiration date.\u003c\/p\u003e\u003cul\u003e\u003cli dir=\"ltr\"\u003e\u003cp dir=\"ltr\"\u003eHanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664107573438,"sku":"HI7061L","price":45.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI7061L.jpg?v=1780546450"},{"product_id":"temperature-probe-for-ph211-each","title":"Temperature probe for pH meter PH211","description":"\u003cp\u003eThe PH211 is a unique innovation-driven product that, thanks to its superior engineering model, is widely accepted in industrial applications as well as in quality control laboratories.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable data-testid=\"specification-attributes\" style=\"margin-right: calc(51%); width: 49%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eCable Length\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-testid=\"specification-attributes-key\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd data-testid=\"specification-attributes-value\"\u003ePhono Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664107999422,"sku":"HI7669-2W","price":215.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI7669.jpg?v=1757382221"},{"product_id":"calibration-standards-for-turbidity-meter-4-standard-set","title":"Turbidity calibration standards","description":"\u003cp\u003eThe HI98703-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 NTU range. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying the appropriate turbidity meter.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSupplied with Certificate of Analysis\u003c\/li\u003e\n\u003cli\u003eAMCO AEPA-1 primary turbidity standards\u003c\/li\u003e\n\u003cli\u003eReusable with long shelf life stability\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe nephelometric turbidity meter is designed to be routinely standardised with a known light scattering standard. As with all analytical standards or reference materials, a turbidity standard should be able to perform the following: provide traceability, demonstrate the accuracy of results, calibrate the equipment and methodology, monitor user performance, validate tests, and facilitate comparability. Standardization ensures that when the correct procedures have been followed, the same analysis of the same materials will produce results that agree with each other whenever they are performed.\u003c\/p\u003e\u003cp\u003eHanna turbidity standards are prepared from AMCO AEPA-1 materials that are known for being highly stable and reliable for standardisation. AMCO APEA-1 turbidity standards are a stabilised suspension of cross linked styrene divinylbenzene copolymer microbeads in ultrapure water. These beads are chemically inert and keep their chemical balance in a water medium regardless of concentration. Particle size, uniform shape, and refractive index make these spheres ideal to characterize light absorption and scatter for 90° behavior in the UV-VIS range. In addition, the bead’s spherical shape and size helps prevent the accumulation or precipitation of the standard. For these reasons, the AMCO AEPA-1 standards are very stable.\u003c\/p\u003e\u003cp\u003eThese standards are prepared and bottled in a clean room facility. They are tested and validated for accuracy and stability, and certified as free from any toxic chemicals or compounds. All prepared standards are compared to formazin turbidity standard solutions. The values obtained and the date of analysis are reported on the supplied corticate of analysis.\u003c\/p\u003e\u003cp\u003eHI98703-11 is a high quality set of turbidity calibration standards that allows users to validate and calibrate turbidity meters that have a 0 to 1000 NTU range. The HI98703-11 set includes four cuvettes with expected readings of \u0026lt;0.10, 15.0, 100, and 750 NTU. The calibration set is produced in our state-of-the-art manufacturing facility using NIST traceable reference materials in a temperature controlled environment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupplied With Certificate Of Analysis\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003cli\u003eStandard value\u003c\/li\u003e\n\u003cli\u003eReference meter NIST traceable\u003c\/li\u003e\n\u003cli\u003eProvided Storage Containers\u003c\/li\u003e\n\u003cli\u003eLight tight\u003c\/li\u003e\n\u003cli\u003eProtects from accidental breakage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHI98703-11 Turbidity calibration standards are made specifically for the HI93414 and HI98703 turbidity meters. The calibration process is quick and easy.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Pack\/4","offer_id":42664108032190,"sku":"HI98703-11","price":292.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI98703-11.jpg?v=1769578025"},{"product_id":"surface-temperature-k-type-thermocouple-probe-with-stainless-steel-tube","title":"Surface temperature K-type thermocouple probe with stainless steel tube","description":"\u003cp\u003eEHI35005 is a hand-held waterproof thermometer using a K-type sensor, together with an advanced microprocessor, to deliver accurate temperature measurement with an extraordinary 1600 hours battery life. Battery level indication with low battery warning and error prevention furnishes this metre with advanced battery management functions.\u003c\/p\u003e\u003cp\u003eThis unit displays current temperature along with the minimum and maximum extremes achieved during the session, on a dual-level LCD. A HOLD button provides the user time to record readings. The °C\/°F button instantly switches between the Celsius and Fahrenheit ranges.\u003c\/p\u003e\u003cp\u003eSelect from a wide variety of interchangeable probes to meet you specific needs. Each probe measures 2 ranges of temperatures, -50.0 to 199.9°C and 200 to 1100°C depending on the probe. Probes are not included with the meter.\u003cbr\u003e\u003cbr\u003e\u003ca class=\"btn\" href=\"https:\/\/proscitech.freshdesk.com\/en\/support\/solutions\/articles\/44001697010-hanna-thermocouple-probes\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003eFor dimly lit areas, HI 935005N is your choice. HI 935005N features a user-activated back-light for low or no light conditions. The CAL button allows the operator to remove the combined metre and probe interchange error in an ice bath at 0°C, for added accuracy and reliability.\u003c\/p\u003e\u003cp\u003eThe HANNA exclusive shockproof rubber boots, HI 710007 and HI 710008, offer maximum impact protection.\u003c\/p\u003e\u003cp\u003eEHI935005 is supplied with batteries, protective case and instructions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.3549%;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 55.4868%;\"\u003eHI766B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.3549%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 55.4868%;\"\u003eSurface K-Type Thermocouple Probe with Handle - HI766B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.3549%;\"\u003eMax. Temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 55.4868%;\"\u003e650°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.3549%;\"\u003eResponse time (90% of final value)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 55.4868%;\"\u003e8 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.3549%;\"\u003eProbe Material\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 55.4868%;\"\u003estainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.3549%;\"\u003eProbe Dimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 55.4868%;\"\u003e200mm L, 16mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.3549%;\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 55.4868%;\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.3549%;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 55.4868%;\"\u003efurnaces, hot solids, moulds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003cbr\u003eEHI710007 Shockproof Rubber Boot, Ergo Style Casing, Blue\u003cbr\u003eEHI710008 Shockproof Rubber Boot, Ergo Style Casing, Orange\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProbes\u003c\/strong\u003e\u003cbr\u003eEHIP766C Penetration Thermocouple Probe\u003cbr\u003eEHIP766D Thermocouple Probes for Air and Gas\u003cbr\u003eEHIP766E1 General Purpose Thermocouple Probe\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664134901950,"sku":"EHIP766B","price":259.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI766B.jpg?v=1757382230"},{"product_id":"general-purpose-probe-max-900-deg-c","title":"General purpose temperature probe, +900C","description":"\u003cp\u003eEHI35005 is a hand-held waterproof thermometer using a K-type sensor, together with an advanced microprocessor, to deliver accurate temperature measurement with an extraordinary 1600 hours battery life. Battery level indication with low battery warning and error prevention furnishes this metre with advanced battery management functions.\u003c\/p\u003e\u003cp\u003eThis unit displays current temperature along with the minimum and maximum extremes achieved during the session, on a dual-level LCD. A HOLD button provides the user time to record readings. The °C\/°F button instantly switches between the Celsius and Fahrenheit ranges.\u003c\/p\u003e\u003cp\u003eSelect from a wide variety of interchangeable probes to meet you specific needs. Each probe measures 2 ranges of temperatures, -50.0 to 199.9°C and 200 to 1100°C depending on the probe. Probes are not included with the meter.\u003cbr\u003e\u003cbr\u003e\u003ca class=\"btn\" href=\"https:\/\/proscitech.freshdesk.com\/en\/support\/solutions\/articles\/44001697010-hanna-thermocouple-probes\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003eFor dimly lit areas, HI 935005N is your choice. HI 935005N features a user-activated back-light for low or no light conditions. The CAL button allows the operator to remove the combined metre and probe interchange error in an ice bath at 0°C, for added accuracy and reliability.\u003c\/p\u003e\u003cp\u003eThe HANNA exclusive shockproof rubber boots, HI 710007 and HI 710008, offer maximum impact protection.\u003c\/p\u003e\u003cp\u003eEHI935005 is supplied with batteries, protective case and instructions.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.5633%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 61.2784%; text-align: center;\"\u003eGeneral Purpose K-Type Thermocouple Probe with Handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.5633%;\"\u003eMax. Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 61.2784%; text-align: center;\"\u003e900°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.5633%;\"\u003eResponse time (90% of final value)\u003c\/td\u003e\n\u003ctd style=\"width: 61.2784%; text-align: center;\"\u003e6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.5633%;\"\u003eProbe Material\u003c\/td\u003e\n\u003ctd style=\"width: 61.2784%; text-align: center;\"\u003estainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.5633%;\"\u003eProbe Dimensions\u003c\/td\u003e\n\u003ctd style=\"width: 61.2784%; text-align: center;\"\u003e120mm L, 3mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.5633%;\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"width: 61.2784%; text-align: center;\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.5633%;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"width: 61.2784%; text-align: center;\"\u003eair, gases, liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003cbr\u003eEHI710007 Shockproof Rubber Boot, Ergo Style Casing, Blue\u003cbr\u003eEHI710008 Shockproof Rubber Boot, Ergo Style Casing, Orange\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProbes\u003c\/strong\u003e\u003cbr\u003eEHIP766C Penetration Thermocouple Probe\u003cbr\u003eEHIP766D Thermocouple Probes for Air and Gas\u003cbr\u003eEHIP766E1 General Purpose Thermocouple Probe\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664134967486,"sku":"EHIP766E1","price":192.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHIP766E1.png?v=1757382233"},{"product_id":"replacement-ph-orp-electrode-for-field-applications","title":"pH\/ORP electrode, gel filled PEI body with BNC connector","description":"\u003cp\u003eThe HI1230B is a PEI body, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass and is protected by an extension of the durable PEI body.\u003c\/p\u003e\u003cp\u003eThis design consideration is ideal for field applications as well as general purpose use.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width: 100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003eHI1230B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003epH: 0 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003edouble, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003eceramic, single \/ 15-20µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003egel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003espheric (dia: 7.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eMatching Pin\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003e2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003e-5 to 70°C – LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003e120mm \/ 163.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003e12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003eCoaxial; 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 43.9338%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"width: 56.0662%; text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664135262398,"sku":"EHIR1230B","price":273.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHIR1230B.jpg?v=1757382234"},{"product_id":"replacement-electrode-for-hi98127-to-hi98130","title":"Replacement electrode for HI98127 to HI98130","description":"\u003cp\u003eThe HI73127 is a spare pH tester electrode that is compatible with: HI98129, and HI98130 Combo multiparameter testers, HI98127 and HI98128 pHep testers, and HI98121 ORP tester. These meters also use HI73127 replaceable electrode that has a stainless steel round connector and extendable cloth junction. This cartridge design has no pins to line up or that can break.\u003c\/p\u003e\u003cp\u003eReplacing a pH electrode on one of Hanna's compatible testers is both quick and easy. The spare electrode is designed as an easy-fit cartridge that locks into place, featuring two o-rings to maintain a watertight seal.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd data-th=\"Product Name\" style=\"text-align: center;\"\u003eElectrode (spare) for HI 98121, HI 98127, HI 98128, HI 98129 and HI 98130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement Range\u003c\/th\u003e\n\u003ctd data-th=\"Measurement Range\" style=\"text-align: center;\"\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference Cell Type\u003c\/th\u003e\n\u003ctd data-th=\"Reference Cell Type\" style=\"text-align: center;\"\u003esingle, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJunction Type\/Flow Rate\u003c\/th\u003e\n\u003ctd data-th=\"Junction Type\/Flow Rate\" style=\"text-align: center;\"\u003ecloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType of Electrolyte\u003c\/th\u003e\n\u003ctd data-th=\"Type of Electrolyte\" style=\"text-align: center;\"\u003egel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBody Material\u003c\/th\u003e\n\u003ctd data-th=\"Body Material\" style=\"text-align: center;\"\u003epolypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTip \/ Shape\u003c\/th\u003e\n\u003ctd data-th=\"Tip \/ Shape\" style=\"text-align: center;\"\u003espheric (diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax. Pressure\u003c\/th\u003e\n\u003ctd data-th=\"Max. Pressure\" style=\"text-align: center;\"\u003e0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Operating Range\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Operating Range\" style=\"text-align: center;\"\u003e-5 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Sensor\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Sensor\" style=\"text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector Type\u003c\/th\u003e\n\u003ctd data-th=\"Connector Type\" style=\"text-align: center;\"\u003epin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmplifier\u003c\/th\u003e\n\u003ctd data-th=\"Amplifier\" style=\"text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended Use\u003c\/th\u003e\n\u003ctd data-th=\"Recommended Use\" style=\"text-align: center;\"\u003efield applications, general purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664135327934,"sku":"EHIR73127","price":165.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/ehi73127_1.jpg?v=1757382237"},{"product_id":"ph-electrode-temp-sensor-refillable-glass-single-junction","title":"Glass pH electrode, hydrocarbons and solvents","description":"\u003cp\u003eThe HI10430 is a glass body, refillable, double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design.\u003c\/p\u003e\u003cp\u003eWithin the probe there is an integrated microchip that stores calibration data, electrode type, and serial number, which allows for changing of sensors without having to recalibrate.\u003c\/p\u003e\u003cp\u003eThe HI10430 has a triple ceramic junction and uses high temperature glass, making it ideal for solutions at temperatures above 30°C. This probe is designed for use with compatible Hanna meters with a 3.5mm input.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003eHI10430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003eDigital Glass Body pH Electrode for Hydrocarbons and Solvents - HI10430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003epH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003edouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003eceramic, triple \/ 40-50 µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eRefill Electrolyte\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003e3.5M KCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003eglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003espheric (dia: 9.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eMatching Pin\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003e0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003e-5 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003e120mm \/ 175.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003e12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003ecoaxial; 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003e3.5mm connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.2467%;\"\u003eRecommended Use\u003c\/td\u003e\n\u003ctd style=\"width: 63.595%; text-align: center;\"\u003ehydrocarbon, low conductivity solutions, paints, sea water, solvents, strong acid and base, tris buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664149876926,"sku":"EHI10430","price":525.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI10430.png?v=1757382239"},{"product_id":"ph-electrode-temp-sensor-refillable-glass-triple-junction-conical-tip","title":"Glass pH electrode, semi-solids and emulsions","description":"\u003cp\u003eThe HI10530 is a digital glass body, refillable, double junction pH electrode that has a built-in temperature sensor. This probe connects to the meter with a 3.5mm connector. The 3.5mm connector is proprietary to meters that use digital electrodes.\u003c\/p\u003e\u003cp\u003eThe HI10530 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a triple ceramic junction in the outer junction and the conical pH sensing portion is made with low temperature glass.\u003c\/p\u003e\u003cp\u003eThis design consideration is ideal for emulsions, fats and creams, soil and semi-solid samples, low conductivity solutions, and for measuring samples at cold temperatures.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBuilt-In Microchip\u003c\/li\u003e\n\u003cli\u003eBuilt-In Temperature Sensor\u003c\/li\u003e\n\u003cli\u003eTriple Ceramic Junction\u003c\/li\u003e\n\u003cli\u003e3.5mm Connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003eDigital Glass Body pH Electrode for Semi-Solids and Emulsions - HI10530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003epH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003edouble, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003eceramic, triple \/ 40-50 µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eRefill Electrolyte\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003e3.5M KCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003eglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003econic (12 x 12mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eMatching Pin\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003e0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003e-5 to 100°C - LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003e120mm \/ 175.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003ecoaxial; 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003e3.5mm connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6676%;\"\u003eRecommended Use\u003c\/td\u003e\n\u003ctd style=\"width: 64.1741%; text-align: center;\"\u003eemulsions, fats and creams, low conductivity solutions, potable water, semi-solid products, soil samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664149942462,"sku":"EHI10530","price":484.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI10530.png?v=1757382242"},{"product_id":"ph-electrode-temp-sensor-refillable-glass-double-junction","title":"Glass pH electrode, general purpose","description":"\u003cp\u003eThe HI11310 is a glass body refillable double junction pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5mm connector. The 3.5mm connector is proprietary to meters that use digital electrodes. This design consideration is ideal for general purpose laboratory use.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBuilt-In Microchip for sensor type, serial number, and calibration information\u003c\/li\u003e\n\u003cli\u003eSpherical glass tip, high temperature glass\u003c\/li\u003e\n\u003cli\u003eSingle ceramic junction\u003c\/li\u003e\n\u003cli\u003eDouble junction reference\u003c\/li\u003e\n\u003cli\u003e3.5mm Connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003eDigital Glass Body pH Electrode for General Purpose - HI11310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003epH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003edouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003eceramic, single \/ 15-20 µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eRefill Electrolyte\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003e3.5M KCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003eglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003espheric (dia: 9.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eMatching Pin\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003e0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003e-5 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003e120mm \/ 175.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003e12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003e3.5 mm connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.3008%;\"\u003eRecommended Use\u003c\/td\u003e\n\u003ctd style=\"width: 59.5409%; text-align: center;\"\u003elaboratory general purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664150270142,"sku":"EHI11310","price":403.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI11310.jpg?v=1780546464"},{"product_id":"ph-electrode-temp-sensor-refillable-glass-double-junction-matching-pin","title":"Glass pH electrode with matching pin, general purpose","description":"\u003cp\u003eThe HI11311 is a glass body, refillable, double junction pH electrode with a matching pin and a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes.\u003c\/p\u003e\u003cp\u003eThe matching pin integrated into the HI11311 is for the Sensor Check capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction.\u003c\/p\u003e\u003cp\u003eThe HI11311 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMatching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction\u003c\/li\u003e\n\u003cli\u003eDouble Junction Reference\u003c\/li\u003e\n\u003cli\u003e3.5mm Connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003eDigital Glass Body pH Electrode with Matching Pin for General Purpose - HI11311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003epH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003edouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003eceramic, single \/ 15-20 µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eRefill Electrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003e3.5M KCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003eglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003espheric (dia: 9.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eMatching Pin\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003e0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003e-5 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003e120mm \/ 195mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003e12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003e3.5 mm connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.0537%;\"\u003eRecommended Use\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 63.788%;\"\u003elaboratory general purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664150368446,"sku":"EHI11311","price":458.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI11311.png?v=1757382247"},{"product_id":"combination-ph-electrode-refillable-bnc-connection","title":"Glass pH electrode with BNC connector, refillable","description":"\u003cp\u003eThe HI1131B is a glass body, refillable, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass.\u003c\/p\u003e\u003cp\u003eThis design consideration is ideal for laboratory samples, beer and other liquid samples, as well as general purpose use.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRefillable Electrode\u003c\/li\u003e\n\u003cli\u003eDouble Junction Design\u003c\/li\u003e\n\u003cli\u003eHigh Temperature (HT) Glass\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"margin-right: calc(0%); width: 100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSingle, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction\/flow rate\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eCeramic, single \/ 15-20µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eKCl 3.5M + AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax pressure\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003epH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended operating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e20 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip\/shape\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSpheric (9.5mm ø)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature sensor\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody material\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eGlass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eCoaxial; 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664150401214,"sku":"EHI1131B","price":361.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI1131B_620c427f-fe1c-47ae-ae7a-27a2a61f1761.jpg?v=1757382257"},{"product_id":"ph-electrode-temp-sensor-gel-filled-pei-double-junction","title":"PEI pH electrode, field applications","description":"\u003cp\u003eThe HI12300 is a plastic body, double junction, gel filled pH electrode with a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5mm connector. The 3.5mm connector is proprietary to meters that use digital electrodes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDigital Electrode with Built-In Microchip\u003c\/li\u003e\n\u003cli\u003eDouble Junction Reference\u003c\/li\u003e\n\u003cli\u003e3.5mm Connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003eDigital PEI Body pH Electrode for Field Applications - HI12300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003epH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003edouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003eceramic, single \/ 15-20 µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003egel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003espheric (dia: 7.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eMatching Pin\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003e2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003e-5 to 70°C - LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003e120mm \/ 163.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003e12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003e3.5 mm connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 39.1077%;\"\u003eRecommended Use\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 59.734%;\"\u003efield applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664150466750,"sku":"EHI12300","price":305.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI12300.png?v=1757382261"},{"product_id":"ph-electrode-temp-sensor-gel-filled-pei-double-junction-matching-pin","title":"PEI pH electrode with matching pin, field applications","description":"\u003cp\u003eThe HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5mm connector. The 3.5mm connector is proprietary to meters that use digital electrodes.\u003c\/p\u003e\u003cp\u003eThe matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction.\u003c\/p\u003e\u003cp\u003eThe HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMatching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction\u003c\/li\u003e\n\u003cli\u003eDouble Junction Reference\u003c\/li\u003e\n\u003cli\u003e3.5mm Connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003eDigital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003epH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003edouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003eceramic, single \/ 15-20 µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003egel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003espheric (dia: 7.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eMatching Pin\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003e2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003e-5 to 70°C - LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003e120mm \/ 181mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003e12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003e3.5 mm connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 38.1425%;\"\u003eRecommended Use\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.6992%;\"\u003efield applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664150532286,"sku":"EHI12301","price":333.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI12301.jpg?v=1757382263"},{"product_id":"magnetic-stirrer-120-x-120-x-45mm-with-12v-adapter","title":"Magnetic stirrer with 12V adapter","description":"\u003cp\u003eCommon stirrers are manufactured with steel and aluminium components. These units are often too large and heavy to fit in the limited space of a laboratory. EHI190MB is compact and lightweight, so that lack of laboratory bench space is no longer a concern.\u003c\/p\u003e\u003cp\u003eThis stirrer incorporates electronic controls allowing the user to regulate the speed with greater precision. Often, in the lab, a sample is removed from the stirrer before reducing the speed which would cause the motor of conventional equipment to accelerate until it is destroyed. This is not the case with the HANNA mini-stirrer. In fact, the internal Speedsafe mechanism will ensure that the maximum speed is never exceeded.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eABS cover will resist the harmful effects of accidently spilt chemicals\u003c\/li\u003e\n\u003cli\u003eMaximum stirring capacity is 1L\u003c\/li\u003e\n\u003cli\u003eEHI190MB is supplied with micro stir bar and instructions\u003c\/li\u003e\n\u003cli\u003eAlso available: HI 200M has an AISI 316 stainless steel cover\u003c\/li\u003e\n\u003cli\u003eModel is ideal for applications that create exothermic reactions\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"margin-right: calc(0%); width: 100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eHI190M-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e12 VDC (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 50°C, RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e120 x 120 x 45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e610g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664150827198,"sku":"EHI190MB","price":215.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/Ehi190m_1.jpg?v=1767316863"},{"product_id":"orp-electrode-for-municipal-water-and-quality-control-bnc-connector-ea","title":"PEI ORP electrode with BNC connector","description":"\u003cp\u003eThe HI3230B is a PEI body, single junction ORP electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the ORP sensing pin is made with platinum. This design consideration is ideal for ORP measurements in municipal water and quality control applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDurable PEI Body\u003c\/li\u003e\n\u003cli\u003eGel Electrolyte\u003c\/li\u003e\n\u003cli\u003ePlatinum Sensing Pin\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd data-th=\"Product Name\" style=\"text-align: center;\"\u003eGel Filled PEI Body ORP Electrode with BNC Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement Range\u003c\/th\u003e\n\u003ctd data-th=\"Measurement Range\" style=\"text-align: center;\"\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference Cell Type\u003c\/th\u003e\n\u003ctd data-th=\"Reference Cell Type\" style=\"text-align: center;\"\u003esingle, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eJunction Type\/Flow Rate\u003c\/th\u003e\n\u003ctd data-th=\"Junction Type\/Flow Rate\" style=\"text-align: center;\"\u003eceramic, single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType of Electrolyte\u003c\/th\u003e\n\u003ctd data-th=\"Type of Electrolyte\" style=\"text-align: center;\"\u003egel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBody Material\u003c\/th\u003e\n\u003ctd data-th=\"Body Material\" style=\"text-align: center;\"\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTip \/ Shape\u003c\/th\u003e\n\u003ctd data-th=\"Tip \/ Shape\" style=\"text-align: center;\"\u003eplatinum pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMatching Pin\u003c\/th\u003e\n\u003ctd data-th=\"Matching Pin\" style=\"text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMax. Pressure\u003c\/th\u003e\n\u003ctd data-th=\"Max. Pressure\" style=\"text-align: center;\"\u003e2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Operating Range\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Operating Range\" style=\"text-align: center;\"\u003e-5 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBody Length\/Overall Length\u003c\/th\u003e\n\u003ctd data-th=\"Body Length\/Overall Length\" style=\"text-align: center;\"\u003e120mm \/ 163.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Sensor\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Sensor\" style=\"text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter Diameter\u003c\/th\u003e\n\u003ctd data-th=\"Outer Diameter\" style=\"text-align: center;\"\u003e12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable\u003c\/th\u003e\n\u003ctd data-th=\"Cable\" style=\"text-align: center;\"\u003ecoaxial; 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector Type\u003c\/th\u003e\n\u003ctd data-th=\"Connector Type\" style=\"text-align: center;\"\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmplifier\u003c\/th\u003e\n\u003ctd data-th=\"Amplifier\" style=\"text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended Use\u003c\/th\u003e\n\u003ctd data-th=\"Recommended Use\" style=\"text-align: center;\"\u003emunicipal water, quality control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eORP Sensing Type\u003c\/th\u003e\n\u003ctd data-th=\"ORP Sensing Type\" style=\"text-align: center;\"\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664151187646,"sku":"EHI3230B","price":396.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI3230B.jpg?v=1757382271"},{"product_id":"hanna-edge-digital-ec-probe","title":"Hanna Edge digital EC probe","description":"\u003cp\u003eThe HI763100 is a digital conductivity electrode with a built-in temperature sensor. Compared to the amperometric design of other conductivity probes, the HI763100 is potentiometric probe with platinum sensors which allows for the possibility to measure high or low conductivity ranges using one probe. This electrode features an integrated microchip which stores calibration data, electrode type, and serial number. The HI763100 is designed for use with Hanna's edge pH\/EC\/DO meter.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDigital Probe with Built-in Microchip\u003c\/li\u003e\n\u003cli\u003eInternal Temperature Sensor\u003c\/li\u003e\n\u003cli\u003e3.5mm Connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca class=\"btn\" href=\"https:\/\/proscitech.freshdesk.com\/en\/support\/solutions\/articles\/44002527316-hanna-edge%C2%AE\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"margin-right: calc(0%); width: 100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eHI763100 - Digital EC\/Temperature Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eEC: 0 to 200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003ePlatinum\/4-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-5 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e120mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eInsulator: glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Meters\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eedge multiparameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664151253182,"sku":"EHI763100","price":912.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/ehi763100.jpg?v=1757390128"},{"product_id":"clark-type-polarographic-dissolved-oxygen-probe","title":"Hanna Edge digital DO probe","description":"\u003cp\u003eThe HI764080 is a digital dissolved oxygen electrode with built-in temperature sensor. This ultra-thin, Clark-type polarographic electrode is designed for measuring DO in aqueous solutions and contains a built-in microchip that stores sensor type, serial number, and calibration information. The sensor features a platinum cathode with a silver\/silver chloride anode, an integrated temperature sensor, and easily replaceable PTFE membrane caps. The HI 764080 is designed for use with Hanna's edge pH\/EC\/DO meter.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDigital Probe\u003c\/li\u003e\n\u003cli\u003eUltra-Thin Body\u003c\/li\u003e\n\u003cli\u003eIntegrated Temperature Sensor\u003c\/li\u003e\n\u003cli\u003e3.5mm Connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca class=\"btn\" href=\"https:\/\/proscitech.freshdesk.com\/en\/support\/solutions\/articles\/44002527316-hanna-edge%C2%AE\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eCompatible Digital DO\/Temperature Electrode - HI764080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003epolarographic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e0 to 300% oxygen saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003ecathode: glass encapsulated platinum; anode: Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e120mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eCable\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003e3.5 mm connector (digital)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.9494%;\"\u003eAmplifier\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 60.8923%;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664151318718,"sku":"EHI764080","price":912.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI764080.jpg?v=1757382277"},{"product_id":"conductivity-meter-with-temperature-sensor-multi-range","title":"Multi-range EC meter with HI76302W probe","description":"\u003cp\u003eDesigned specifically for use in areas of production and quality control. It is often necessary to test samples with different concentrations ranging from deionised water to brine.\u003c\/p\u003e\u003cp\u003eThe amperometric system would require constant recalibration and probe changes, thus making the measurement process very time consuming and unreliable. To solve this problem, HANNA ; has developed the EHI8633, which uses a 4-ring potentiometric probe. The rugged probe is made of PVC - ideal for indoor, as well as outdoor measurements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIt is possible to obtain accurate readings across a very wide range, from 0.1 to 199900 µS\/cm using one point calibration.\u003c\/li\u003e\n\u003cli\u003eEHI8733 has a built-in temperature sensor and Automatic Temperature Compensation for temperature fluctuations.\u003c\/li\u003e\n\u003cli\u003eEHI8733 is supplied with HI76302W probe with internal temperature sensor and 1m cable, calibration screwdriver, calibration solutions, protective case, battery and instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHI710133 is available as an accessory - This kit includes a rugged carrying case with a beaker, a calibration screwdriver and standardising solution at 12880µS\/cm.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd data-th=\"Product Name\" style=\"text-align: center; width: 69.7726%;\"\u003eMulti-range EC meter with HI76302W probe, Range: 0.0 to 199.9 mS\/cm w\/ATC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eQuote Required\u003c\/th\u003e\n\u003ctd data-th=\"Quote Required\" style=\"text-align: center; width: 69.7726%;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eEC Range\u003c\/th\u003e\n\u003ctd data-th=\"EC Range\" style=\"text-align: center; width: 69.7726%;\"\u003e0.0 to 199.9µS\/cm; 0 to 1999µS\/cm; 0.00 to 19.99mS\/cm; 0.0 to 199.9mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eEC Resolution\u003c\/th\u003e\n\u003ctd data-th=\"EC Resolution\" style=\"text-align: center; width: 69.7726%;\"\u003e0.1µS\/cm; 1µS\/cm; 0.01mS\/cm; 0.1mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eEC Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"EC Accuracy\" style=\"text-align: center; width: 69.7726%;\"\u003e±1% FS (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eEC Calibration\u003c\/th\u003e\n\u003ctd data-th=\"EC Calibration\" style=\"text-align: center; width: 69.7726%;\"\u003emanual, one-point through EC knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eEC\/TDS Temperature Compensation\u003c\/th\u003e\n\u003ctd data-th=\"EC\/TDS Temperature Compensation\" style=\"text-align: center; width: 69.7726%;\"\u003eautomatic, 0 to 50°C with β adjustable from 0 to 2.5%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eEC\/TDS Probe\u003c\/th\u003e\n\u003ctd data-th=\"EC\/TDS Probe\" style=\"text-align: center; width: 69.7726%;\"\u003eHI76302W conductivity probe with internal temperature sensor, DIN connector and 1m cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd data-th=\"Battery Type\/Life\" style=\"text-align: center; width: 69.7726%;\"\u003e9V \/ approximately 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd data-th=\"Environment\" style=\"text-align: center; width: 69.7726%;\"\u003e0 to 50°C; RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 29.0691%;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" style=\"text-align: center; width: 69.7726%;\"\u003e145 x 80 x 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664151351486,"sku":"EHI8733","price":1017.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/Ehi8733.jpg?v=1757382280"},{"product_id":"tds-meter-portable-waterproof-wide-range","title":"TDS wide range meter, waterproof","description":"\u003cp\u003eThe HI8734 is a rugged, portable TDS meter designed for the water conditioning industry, particularly in the softening, demineralisation, reverse osmosis, and drinking water applications. It can also be used for a wide variety of environmental conditions. TDS readings are adjusted with manual temperature compensation, assuring users of consistent and accurate measurements of total dissolved solids.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFour-ring probe\u003c\/li\u003e\n\u003cli\u003emeasurement ranges from 0.0mg\/L to 19.99g\/L with a ±1% FS accuracy\u003c\/li\u003e\n\u003cli\u003eManual Temperature Compensation\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd data-th=\"Product Name\" style=\"text-align: center;\"\u003eTDS meter, Range: 0.0 to 199.9mg\/L (ppm); 0 to 1999mg\/L (ppm); 0.00 to 19.99g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eQuote Required\u003c\/th\u003e\n\u003ctd data-th=\"Quote Required\" style=\"text-align: center;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTDS Range\u003c\/th\u003e\n\u003ctd data-th=\"TDS Range\" style=\"text-align: center;\"\u003e0.0 to 199.9mg\/L (ppm); 0 to 1999mg\/L (ppm); 0.00 to 19.99g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTDS Resolution\u003c\/th\u003e\n\u003ctd data-th=\"TDS Resolution\" style=\"text-align: center;\"\u003e0.1mg\/L (ppm); 1mg\/L (ppm); 0.01g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTDS Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"TDS Accuracy\" style=\"text-align: center;\"\u003e±1% FS (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTDS Calibration\u003c\/th\u003e\n\u003ctd data-th=\"TDS Calibration\" style=\"text-align: center;\"\u003emanual, one-point through TDS knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC\/TDS Temperature Compensation\u003c\/th\u003e\n\u003ctd data-th=\"EC\/TDS Temperature Compensation\" style=\"text-align: center;\"\u003emanual from 0 to 50°C with β = 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC to TDS Conversion Factor\u003c\/th\u003e\n\u003ctd data-th=\"EC to TDS Conversion Factor\" style=\"text-align: center;\"\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC\/TDS Probe\u003c\/th\u003e\n\u003ctd data-th=\"EC\/TDS Probe\" style=\"text-align: center;\"\u003eHI76301D four ring conductivity probe with DIN connector and 1m cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd data-th=\"Battery Type\/Life\" style=\"text-align: center;\"\u003e9V \/ approximately 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd data-th=\"Environment\" style=\"text-align: center;\"\u003e0 to 50°C; RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" style=\"text-align: center;\"\u003e145 x 80 x 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd data-th=\"Weight\" style=\"text-align: center;\"\u003e230g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664151449790,"sku":"EHI8734","price":1011.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/Ehi8734.jpg?v=1757382282"},{"product_id":"dissolved-oxygen-meter-portable-10m-probe-cable","title":"Dissolved oxygen meter with 10m probe cable","description":"\u003cp\u003eEHI9146 is a water-resistant, microprocessor-based, dissolved oxygen meter with automatic temperature compensation (ATC). This meter also allows manual compensation of altitude and salinity values. The polarographic probe, supplied with the instrument, is provided with a protective cover for the membrane. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFetaures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDO measurements can be displayed in parts per million (ppm=mg\/L) or in % of saturation. \u003c\/li\u003e\n\u003cli\u003eTemperature range is indicated in Celsius from 0 to 50°C with 0.1°C resolution. \u003c\/li\u003e\n\u003cli\u003eHOLD button allows the user to freeze the reading on the LCD. \u003c\/li\u003e\n\u003cli\u003eEHI9146 can be powered with batteries (with low battery indicator) or through a 12 VDC adapter.\u003c\/li\u003e\n\u003cli\u003eEHI9146-10 is supplied with HI 76407\/10F probe with 10m cable and protective cap, 2 spare membranes, HI 7041S electrolyte solution (30ml), batteries, hard carrying case and instructions.\u003c\/li\u003e\n\u003cli\u003eEHI9146-04 comes with a 4m probe cable.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd data-th=\"Product Name\" style=\"text-align: center;\"\u003ePortable Dissolved Oxygen Meter - HI9146\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDissolved Oxygen Range\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Range\" style=\"text-align: center;\"\u003e0.00 to 45.00 ppm (mg\/L), 0.0 up to 300.0% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDissolved Oxygen Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Resolution\" style=\"text-align: center;\"\u003e0.01ppm (mg\/L); 0.1% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDissolved Oxygen Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Accuracy \" style=\"text-align: center;\"\u003e±1.5% F.S. or ±1 digit, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDissolved Oxygen Calibration\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Calibration\" style=\"text-align: center;\"\u003eone or two points at 0% (HI 7040 solution) and 100% (in air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDissolved Oxygen Temperature Compensation\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Temperature Compensation\" style=\"text-align: center;\"\u003eautomatic from 0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSalinity Compensation\u003c\/th\u003e\n\u003ctd data-th=\"Salinity Compensation\" style=\"text-align: center;\"\u003e0 to 80g\/L (ppt) (resolution 1g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAltitude Compensation\u003c\/th\u003e\n\u003ctd data-th=\"Altitude Compensation\" style=\"text-align: center;\"\u003e0 to 4000m (resolution 100m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Range\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Range\" style=\"text-align: center;\"\u003e0.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Resolution\" style=\"text-align: center;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Accuracy\" style=\"text-align: center;\"\u003e±0.2°C (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDO Probe\u003c\/th\u003e\n\u003ctd data-th=\"DO Probe\" style=\"text-align: center;\"\u003eHI76407 DO probe (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd data-th=\"Battery Type\/Life\" style=\"text-align: center;\"\u003e1.5V AAA (3) \/approximately 200 hours of continuous use without backlight (50 hours with backlight on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd data-th=\"Environment\" style=\"text-align: center;\"\u003e0 to 50°C; RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" style=\"text-align: center;\"\u003e185 x 72 x 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd data-th=\"Weight\" style=\"text-align: center;\"\u003e300g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664154136766,"sku":"EHI9146-10","price":1446.2,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/ehi9146-10.jpg?v=1757382285"},{"product_id":"k-type-thermometer-waterproof-dual-range","title":"K-type dual range thermometer, waterproof","description":"\u003cp\u003eA hand-held waterproof thermometer using a K-type sensor, together with an advanced microprocessor, to deliver accurate temperature measurement with an extraordinary 1600 hours battery life. Battery level indication with low battery warning and error prevention furnishes this meter with advanced battery management functions.\u003c\/p\u003e\u003cp\u003eThis unit displays current temperature along with the minimum and maximum extremes achieved during the session, on a dual-level LCD. A HOLD button provides the user time to record readings. The°C\/°F button instantly switches between the Celsius and Fahrenheit ranges.\u003c\/p\u003e\u003cp\u003eSelect from a wide variety of interchangeable probes to meet your specific needs. Each probe measures 2 ranges of temperatures, -50.0 to 199.9°C and 200 to 1100°C depending on the probe. Probes are not included with the meter.\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/proscitech.freshdesk.com\/en\/support\/solutions\/articles\/44001697010-hanna-thermocouple-probes\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Thermocouple Probes\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003eFor dimly lit areas, HI 935005N is your choice. HI 935005N features a user-activated back-light for low or no light conditions. The CAL button allows the operator to remove the combined metre and probe interchange error in an ice bath at 0°C, for added accuracy and reliability.\u003cbr\u003eThe HANNA exclusive shockproof rubber boots, HI 710007 and HI 710008, offer maximum impact protection.\u003cbr\u003eEHI935005 is supplied with batteries, protective case and instructions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003eK-Type Thermocouple Thermometer with Auto-off Capability - HI935005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eK-Type Thermocouple Temperature Range\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003e-50.0 to 199.9°C \/ 200 to 1350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eK-Type Thermocouple Temperature Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003e0.1°C (up to 199.9°C) \/ 1°C (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eK-Type Thermocouple Temperature Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003e±0.2% FS (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003eHI766 series K-type thermocouple (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003e8 min (default), 60 min or OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003e1.5V AA (3) \/ approximately 1600 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003e-10 to 50°C; RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003e150 x 80 x 36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5364%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 65.3053%; text-align: center;\"\u003e235g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003cbr\u003eEHI710007 Shockproof Rubber Boot, Ergo Style Casing, Blue\u003cbr\u003eEHI710008 Shockproof Rubber Boot, Ergo Style Casing, Orange\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProbes\u003c\/strong\u003e\u003cbr\u003eEHIP766C Penetration Thermocouple Probe\u003cbr\u003eEHIP766D Thermocouple Probes for Air and Gas\u003cbr\u003eEHIP766E1 General Purpose Thermocouple Probe\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664154169534,"sku":"EHI935005","price":308.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/Ehi935005.jpg?v=1757382287"},{"product_id":"turbidity-meter-portable-iso-compliant","title":"Portable turbidity meter kit, ISO compliant","description":"\u003cp\u003eA microprocessor-based turbidity meter that provides laboratory precision for field turbidity measurements. It is designed to deliver a simple yet accurate way to test turbidity on-site.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTwo operating ranges: 0.00 to 50.00 FTUs, and 50 to 1000 FTU, which can accommodate the most turbid conditions.\u003c\/li\u003e\n\u003cli\u003eEHI93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.\u003c\/li\u003e\n\u003cli\u003eMeets the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.\u003c\/li\u003e\n\u003cli\u003eEHI93703 is supplied with glass cuvet, batteries and instructions.\u003c\/li\u003e\n\u003cli\u003eComplete kit includes meter and HI731313 maintenance kit: rugged carry case 340 x 230 x 90mm, 2 x calibration solutions, cuvette cleaning solution, cuvette cleaning cloth and 2 cuvettes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eTurbidity of water is an optical property that causes light to be scattered and absorbed, rather than transmitted and is caused by suspended solids.\u003cbr\u003eThe higher the turbidity, the greater the amount of scattered light. Even a very pure fluid will scatter light to a certain degree; no solution will have zero turbidity.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003eHI93703 Portable Turbidity Meter ISO Compliant-meter only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eTurbidity Range\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003e0.00 to 1000 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003e0.01 (0.00 to 50.00 FTU); 1 (50 to 1000 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eTurbidity Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003e±0.5 FTU or ±5% of reading (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eTurbidity Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003ethree points (0 FTU, 10 FTU and 500 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eTurbidity Light Source\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eTurbidity Light Detector\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003einfrared LED \/ life of instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003e1.5V AA (4) \/approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003e0 to 50°C; RH max 95% (non condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003e220 x 82 x 66mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0886%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 67.7531%; text-align: center;\"\u003e510g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Standard \/ Each","offer_id":42664154235070,"sku":"EHI93703","price":1787.09,"currency_code":"AUD","in_stock":true},{"title":"Complete kit \/ Each","offer_id":42664154267838,"sku":"EHI93703C","price":2016.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI93703.png?v=1757382290"},{"product_id":"digital-refractometer","title":"Digital refractometers","description":"\u003cp\u003eRugged, portable, water resistant (IP65) meters which employ the measurement of refractive index to display the sugar content in samples. Samples are measured after a simple user calibration with deionised or distilled water. Within seconds the instrument measures the refractive index of the sample and converts it to % Brix concentration units. Digital refractometers eliminate the uncertainty associated with mechanical refractometers and are portable for measurements in the field.\u003cbr\u003eThe measurement technique and temperature compensation employ the methodology in the ICUMSA Methods Book (International Commission for Uniform Methods of Sugar Analysis). EHI96801 and EHI96811 are supplied with 1 x 9V battery and instructions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTemperature (in °C or °F) is displayed simultaneously with measurement on the large, dual level display along with other helpful message codes.\u003c\/li\u003e\n\u003cli\u003eThe wide range suits most applications and the meters are easy to operate. \u003c\/li\u003e\n\u003cli\u003eFill the sample well with distilled or deionised water and press the ZERO key. \u003c\/li\u003e\n\u003cli\u003ePlace a few drops of the sample in the well and press the READ key. \u003c\/li\u003e\n\u003cli\u003eTemperature is automatically compensated (ATC). \u003c\/li\u003e\n\u003cli\u003eThe refractometers are operated by a single 9V battery for portability and the dual-level LCD displays the measurement as well as temperature readings simultaneously in approx. 1.5 seconds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e EHI96811 wine refractometer can only measure grape juice, not finished wine, as the alcohol in the wine affects the Brix reading.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 19.1934%; text-align: center;\"\u003eHI96801\u003c\/td\u003e\n\u003ctd style=\"width: 21.0077%; text-align: center;\"\u003eHI96811\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 19.305%; text-align: center;\"\u003eHI96831\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 19.1506%; text-align: center;\"\u003eHI96832\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"width: 19.1934%; text-align: center;\"\u003eBrix Analysis in Foods\u003c\/td\u003e\n\u003ctd style=\"width: 21.0077%; text-align: center;\"\u003eBrix Analysis in Wine, Must and Juice\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 19.305%; text-align: center;\"\u003eEthylene Glycol Analysis\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 19.1506%; text-align: center;\"\u003ePropylene Glycol Analysis\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eSugar Content Range\u003c\/td\u003e\n\u003ctd style=\"width: 19.1934%; text-align: center;\"\u003e0 to 85% Brix\u003c\/td\u003e\n\u003ctd style=\"width: 21.0077%; text-align: center;\"\u003e0 to 50% Brix\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"3\" style=\"width: 37.2587%; text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eSugar Content Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 40.0428%; text-align: center;\"\u003e0.1% Brix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eSugar Content Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 40.0428%; text-align: center;\"\u003e±0.2% Brix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eEthylene Glycol Range\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"3\" style=\"width: 40.0428%; text-align: center;\"\u003e-\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 100%\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"3\" style=\"text-align: center; width: 18.7259%;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eEthylene Glycol Resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eEthylene Glycol Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.2%\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePropylene Glycol Range\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\" rowspan=\"3\" style=\"width: 58.4942%; text-align: center;\"\u003e-\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 100%\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePropylene Glycol Resolution\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.1%\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePropylene Glycol Accuracy\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.3%\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.9923%; text-align: center;\"\u003e0°C to 80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003e0.1°C\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003e±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003eautomatic between 10 and 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003eafter three minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003e9V \/ approximately 5000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003e192 x 102 x 67mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003e420g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eRefractometer Light Source\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003eyellow LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eMinimum Sample Volume\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003e100 µL (to cover prism totally)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eSample Cell\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003estainless steel ring and flint glass prism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.768%;\"\u003eMeasurement Time\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 77.6062%; text-align: center;\"\u003eapproximately 1.5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Brix 0 - 85% \/ Each","offer_id":42664154562750,"sku":"EHI96801","price":533.0,"currency_code":"AUD","in_stock":true},{"title":"Brix 0 - 50% \/ Each","offer_id":42664154595518,"sku":"EHI96811","price":532.0,"currency_code":"AUD","in_stock":true},{"title":"Ethylene glycol \/ Each","offer_id":42664154628286,"sku":"EHI96831","price":532.0,"currency_code":"AUD","in_stock":true},{"title":"Propylene glycol \/ Each","offer_id":42664154661054,"sku":"EHI96832","price":532.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI-DIGRFT.jpg?v=1767317725"},{"product_id":"light-meter-multi-range","title":"Portable multi-range lux meter","description":"\u003cp\u003eA portable lux meter designed to perform light measurements with ease. The light sensor is connected to the meter through a coaxial cable, allowing measurements from a distance without any interference from the operator.\u003c\/p\u003e\u003cp\u003eBy simply pressing the RANGE key, it is possible to switch among three ranges and choose the best resolution according to the environment to be tested. The meter has a rugged and water-resistant body for outdoor use. The 9V battery and automatic shut-off feature guarantee about 200 hours of operation.\u003c\/p\u003e\u003cp\u003eEHI97500 is supplied with battery, protective case and instructions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003ePortable Lux Meter - HI97500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLux Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.001 to 1.999 Klux; 0.01 to 19.99 Klux; 0.1 to 199.9 Klux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLux Resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.001 Klux; 0.01 Klux; 0.1 Klux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLux Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±6% of reading ±2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLux Sensor\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003ehuman-eye-response silicon photodiode with 1.5m coaxial cable (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e9V \/ approximately 200 hours of continuous use; auto-off after 7 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 50°C; RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e164 x 76 x 45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e180g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664154792126,"sku":"EHI97500","price":351.22,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/Ehi97500.jpg?v=1757382296"},{"product_id":"water-quality-meter-multi-parameter","title":"HI9829 multiparameter water meter, waterproof with GPS","description":"\u003cp\u003eThe HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customisable and supplied with all necessary accessories, packaged in a durable carrying case.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eField replaceable ISO 7027 compliant turbidity sensor\u003c\/li\u003e\n\u003cli\u003eAmmonium, chloride and nitrate ISE's\u003c\/li\u003e\n\u003cli\u003eLogging from probe or meter\u003c\/li\u003e\n\u003cli\u003eFully customisable instrument, probe, sensors and measurement specifications\u003c\/li\u003e\n\u003cli\u003eDisplay from 1 to 12 parameters with font dimension adjustment\u003c\/li\u003e\n\u003cli\u003eField replaceable sensors\u003c\/li\u003e\n\u003cli\u003epH\/ORP or pH, four electrode EC and \u003ca href=\"https:\/\/proscitech.com.au\/collections\/ins-meter-accessories-and-spares\/products\/galvanic-do-sensor-for-hi9829-multiparameter-portable-meter\" rel=\"noopener noreferrer\" target=\"_blank\"\u003egalvanic DO sensors\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eAuto-recognition of all sensors\u003c\/li\u003e\n\u003cli\u003eRugged probe with stainless steel tip has a diameter under 2\" for wells and pipes\u003c\/li\u003e\n\u003cli\u003eFast Tracker-Tag I.D. System simplifies periodic monitoring\u003c\/li\u003e\n\u003cli\u003eFeatures a built-in barometer for DO compensation\u003c\/li\u003e\n\u003cli\u003eQuick or independent sensor calibration feature\u003c\/li\u003e\n\u003cli\u003eMeasurement check eliminates erroneous readings\u003c\/li\u003e\n\u003cli\u003eLogged data can be displayed as graphs\u003c\/li\u003e\n\u003cli\u003eGraphic LCD with backlight\u003c\/li\u003e\n\u003cli\u003eUSB for PC connectivity\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice feature with last five calibrations recorded\u003c\/li\u003e\n\u003cli\u003eMeter accepts both alkaline and rechargeable batteries\u003c\/li\u003e\n\u003cli\u003eWaterproof protection for meter (IP67) and probes (IP 68)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca class=\"btn\" href=\"https:\/\/proscitech.freshdesk.com\/en\/support\/solutions\/articles\/44001695202-hi9829-hanna-multiparameter-meters\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eHI9829 Multiparameter pH\/ISE\/EC\/DO\/Turbidity Waterproof Meter with GPS option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003epH Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003epH Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eautomatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eORP Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±1.0mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eORP Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eautomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003emV Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±0.5mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eEC Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0 to 200mS\/cm (absolute EC up to 400mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eEC Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eManual: 1µS\/cm; 0.001mS\/cm; 0.01mS\/cm; 0.1mS\/cm; 1mS\/cm, Automatic: 1µS\/cm from 0 to 9999µS\/cm; 0.01mS\/cm from 10.00 to 99.99mS\/cm; 0.1mS\/cm from 100.0 to 400.0mS\/cm, Automatic (mS\/cm): 0.001mS\/cm from 0.000 to 9.999mS\/cm; 0.01mS\/cm from 10.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±1% of reading or ±1µS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eEC Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eautomatic single point, with six standard solutions (84µS\/cm, 1413µS\/cm, 5.00mS\/cm, 12.88mS\/cm, 80.0mS\/cm, 111.8mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0 to 400000ppm (mg\/L); (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eManual: 1ppm (mg\/L); 0.001ppt (g\/L); 0.01ppt (g\/L); 0.1 ppt (g\/L); 1ppt (g\/L), Automatic: 1ppm (mg\/L) from 0 to 9999ppm (mg\/L); 0.01ppt (g\/L) from 10.00 to 99.99ppt (g\/L); 0.1ppt (g\/L) from 100.0 to 400.0ppt (g\/L), Automatic ppt (g\/L): 0.001ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±1% of reading or ±1 ppm (mg\/L), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eSalinity (Seawater Sigma) Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.0 to 50.0 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eSalinity (Seawater Sigma) Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eSalinity (Seawater Sigma) Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eSalinity (Seawater Sigma) Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eResistivity Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0 to 999999 Ω cm; 0 to 1000.0 kΩ cm; 0 to 1.0000 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003edependent on resistivity reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.0 to 500.0%; 0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.1%; 0.01ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00ppm (mg\/L): ±1.5% of reading or ±0.10ppm (mg\/L), whichever is greater, 30.00ppm (mg\/L) to 50.00ppm (mg\/L): ±3% of reading, 300.0 to 500.0% saturation: ±3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eautomatic one or two points at 0 and 100% or one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTurbidity Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.0 to 99.9 FNU; 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTurbidity Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±0.3 FNU or ±2 % of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTurbidity Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eAutomatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e-5.00 to 55.00°C,  268.15 to 328.15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.01K, 0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±0.15°C; ±0.15K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eautomatic from -5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eAmmonium Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.02 to 200ppm as NH\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e+\u003c\/sup\u003e-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eAmmonium Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.01ppm to 1ppm 0.1 ppm to 200.0ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eAmmonium Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±5 % reading or 2ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eAmmonium Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e1 or 2 point, 10ppm and 100ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eChloride Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.6 to 200.0 ppm Cl (as Cl- )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.01ppm to 1ppm 0.1ppm to 200.0ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eChloride Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e±5 % of reading or 2ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eChloride Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e1 or 2 point, 10ppm and 100ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eNitrate Range\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.62 to 200.0ppm Ni (as NO3 - -N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0.01ppm to 1ppm 0.1ppm to 200ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eNitrate Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e1 or 2 point, 10ppm and 100ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eLogging Memory\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e44,000 records (continuous logging or log-on-demand of all parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eLogging Interval\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eUSB (with HI 929829 software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eIP Protection\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e0 to 50°C, RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e221 x 115 x 55mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e750g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 27.2125%;\"\u003eGPS\u003c\/td\u003e\n\u003ctd style=\"width: 71.6292%; text-align: center;\"\u003e12 channel receiver 10m accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSupplied as a kit. This meter will also take a turbidity sensor (cheaper to order a turbidity capable kit then add it later if turbidity is required) as well as ISE sensors which can be added later.\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSoftware is supplied.\u003c\/em\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Standard \/ Each","offer_id":42664154857662,"sku":"EHI9829-00042","price":6094.7,"currency_code":"AUD","in_stock":true},{"title":"Turbidity included \/ Each","offer_id":42664154890430,"sku":"EHI9829-01042","price":6359.15,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI9829-11042a.png?v=1757390140"},{"product_id":"probe-thermometer-50-to-150-deg-c-accuracy-0-3-deg-c","title":"Probe thermometer, -50 to +150C","description":"\u003cp\u003eCheckTemp gives a temperature readout from -50 to 150°C in seconds on a large LCD with ±0.3°C accuracy.\u003c\/p\u003e\u003cp\u003eCheckTemp incorporates a unique Calibration Check function; simply activate the proper switch and the instrument will simulate 0.0°C signal that has to be read on the LCD within a range of ±0.3°C. This system guarantees the accuracy of your measurement at any time.\u003c\/p\u003e\u003cp\u003eThe sharp-tip probe can easily penetrate semisolid products such as fruits, vegetables and cheese, making routine controls simple and quick for both incoming and outgoing goods. The AISI 316 stainless steel material of the probe is in compliance with food regulations.\u003cbr\u003eCheckTemp is the ideal instrument for measuring temperature according to HACCP requirements.\u003cbr\u003e\u003cbr\u003eEHI98501 (CheckTemp C) is supplied with penetration probe, protective cap, battery and instructions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e±0.2°C – Accuracy\u003c\/li\u003e\n\u003cli\u003eMost accurate temperature tester in the world\u003c\/li\u003e\n\u003cli\u003eCAL Check – Automatically verifies calibration at startup\u003c\/li\u003e\n\u003cli\u003e°C\/°F Status – User selectable\u003c\/li\u003e\n\u003cli\u003eLarge display with wide environmental temperature range and viewing angle.\u003c\/li\u003e\n\u003cli\u003eIP 65 water resistant protection\u003c\/li\u003e\n\u003cli\u003eHACCP Compatible – Use as a tool for control in HACCP analysis\u003c\/li\u003e\n\u003cli\u003eAISI 316 stainless steel penetration Probe\u003c\/li\u003e\n\u003cli\u003e3000 hours of battery life (Continuous use)\u003c\/li\u003e\n\u003cli\u003eAuto-Off (select from 8 min., 60 min., or turn the feature off)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664154955966,"sku":"EHI98501","price":113.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI98501.jpg?v=1757390144"},{"product_id":"thermometer-with-ss-probe-1m-cable-50-to-150-deg-c-accuracy-0-3-deg-c","title":"Thermometer with SS probe, -50 to +150C","description":"\u003cp\u003eChecktemp 1 is a high accuracy thermometer with a stainless steel probe on a 1m flexible cable. This penetration probe is perfect for fast response in liquids, air, frozen and semisolid materials. It utilises a high-tech NTC thermistor sensor to measure the temperature. Thermistors make it possible to obtain extremely high accuracy in a very short period of time.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCalibration test device incorporated into the meter. Activate the \"test\" switch and this device will simulate a 0.0°C signal that has to be read on the LCD within a range of ±0.3°C.\u003c\/li\u003e\n\u003cli\u003eSharp-tip probe easily penetrates semisolid products such as fruits, vegetables and cheese. \u003c\/li\u003e\n\u003cli\u003eRoutine controls are fast and simple for both incoming and outgoing goods. \u003c\/li\u003e\n\u003cli\u003eConstructed of AISI 316 stainless steel material, this probe is in compliance with food regulations.\u003c\/li\u003e\n\u003cli\u003eIdeal instrument for measuring temperature according to HACCP requirements.\u003c\/li\u003e\n\u003cli\u003eEHI98509 (Checktemp 1 C) is supplied with battery and instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003eChecktemp 1 Digital Thermometer - HI98509\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003e-50.0 to 150.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003e0.1°C (-50.0 to 150.0°C)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003e±0.2°C (-30.0 to 120.0°C)\u003cbr\u003e±0.3°C (outside: -50.0 to -30.0°C and 120.0 to 150.0°C)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003estainless steel, 1m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003e8 min (default), 60 min or OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003e3 x 1.5 V AAA alkaline; approx. 2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003e-30 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003e107 x 59 x 17mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003e130g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4476%;\"\u003eNotes\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 68.3941%;\"\u003eCertication: EN 13485:2001 - Suitability: Storage; Environment: E; Accuracy Class: 0.5; Protection: IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eAlso available: Checktemp ; Dip (HI 98509-01) with a weighted probe on a flexible 3m cable, ideal for measurements in tanks.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664155021502,"sku":"EHI98509","price":118.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/Ehi98509.jpg?v=1780631716"},{"product_id":"turbidity-meter-portable-epa-compliant","title":"Portable turbidity meter, EPA compliant","description":"\u003cp\u003eThis portable turbidity meter utilises an EPA compliant tungsten light source and state-of-the-art optical system that allows consistently reliable and accurate measurements for turbidity. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.\u003c\/p\u003e\u003cp\u003eTo meet EPA reporting requirements, these instruments have an EPA compliance reading mode. EHI98703 meets all EPA requirements with regards to the Standard Methods for Turbidity Measurements. Turbidity is measured up to 1000 NTU. Depending on the measured sample and required accuracy, users can select normal measurement, continuous measurement or signal averaging.\u003c\/p\u003e\u003cp\u003eIHI98703 can be equipped with HANNA's (optional) Tag Identification System (TIS), which allows users to record the time and location of a specific measurement or series of measurements. Logged data can be downloaded to a PC through either USB or RS232 connections.\u003c\/p\u003e\u003cp\u003eReliable performance of the instrument is validated using Hanna's exclusive Cal Check system and our ready-made, NIST traceable chlorine standards. For turbidity, a two, three or four-point calibration is available using pre-set or user defined standards. Frequent calibration is not necessary as the system compensates for variations in the intensity of the light source.\u003c\/p\u003e\u003cp\u003eThe instruments' Good Laboratory Practice functions allow traceability of calibration conditions including the time, date and last calibration points.\u003cbr\u003eAt start-up, the meter displays the percentage of remaining battery life. A 'low battery' warning message is also displayed on the LCD to avoid unexpected battery failure. This instruments is equipped with backlighting. The current date and time can be displayed on the LCD.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEHI98703 includes:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFive sample cuvets and caps\u003c\/li\u003e\n\u003cli\u003eCalibration cuvets (HI 98703-11)\u003c\/li\u003e\n\u003cli\u003eSilicone oil (HI 93703-58)\u003c\/li\u003e\n\u003cli\u003eTissue for wiping the cuvets\u003c\/li\u003e\n\u003cli\u003eFive tag holders with tags (HI 920005)\u003c\/li\u003e\n\u003cli\u003eFour batteries\u003c\/li\u003e\n\u003cli\u003eAC adapter\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eRigid carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eTurbidity of water is an optical property that causes light to be scattered and absorbed, rather than transmitted and is caused by suspended solids.\u003cbr\u003eThe higher the turbidity, the greater the amount of scattered light. Even a very pure fluid will scatter light to a certain degree; no solution will have zero turbidity.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003eTurbidity (EPA) Portable Meter - HI98703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e0.01; 0.1; 1 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e±2% of reading plus 0.02 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Repeatability\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e±1% of reading or 0.02 NTU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Stray Light\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e\u0026lt; 0.02 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Calibration\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003etwo, three, or four-point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Measuring Method\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003eratio nephelometric method (90° \u0026amp; 180°). Adaptation of the USEPA Method 180.1 and Standard Method 2130 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Measuring Modes\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003enormal, average, continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Light Source\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003etungsten filament lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eTurbidity Light Detector\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eLogging Memory\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e200 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003eUSB or RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003eauto-off after 15 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e60 x 90mm backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e4 (1.5V) AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e4 (1.5V) AA alkaline batteries or AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e0 to 50°C, RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e224 x 87 x 77mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.5093%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 65.3324%;\"\u003e512g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664155185342,"sku":"EHI98703","price":2417.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI98703.jpg?v=1765922333"},{"product_id":"ph-ec-tds-deg-c-meter-waterproof","title":"Portable pH\/EC\/TDS meters, waterproof","description":"\u003cp\u003eDesigned to bring simplicity to environmental testing, the EHI991300 low range EC \/ EHI991301 high range EC pH\/EC\/TDS Meter is designed specifically for use in manufacturing and environmental testing protocols. The specialised electrode combines 3 sensors in a single rugged probe body featuring a polypropylene body, integrated temperature sensor, and cloth junction.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e3-in-1 probe measures pH, EC\/TDS, and temperature.\u003c\/li\u003e\n\u003cli\u003eComes with all the necessary solutions and batteries- everything you need to get started measuring right away.\u003c\/li\u003e\n\u003cli\u003ePerfect for water quality testing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eCode\u003c\/td\u003e\n\u003ctd style=\"width: 37.7263%; text-align: center;\"\u003eHI991300\u003c\/td\u003e\n\u003ctd style=\"width: 37.1275%; text-align: center;\"\u003eHI991301\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eName\u003c\/td\u003e\n\u003ctd style=\"width: 37.7263%; text-align: center;\"\u003ePortable Waterproof pH\/EC\/TDS Meter (Low Range)\u003c\/td\u003e\n\u003ctd style=\"width: 37.1275%; text-align: center;\"\u003ePortable Waterproof pH\/EC\/TDS Meter (High Range)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003epH Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e‐2.00 to 16.00 pH; ‐2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e0.01 pH; 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e±0.02 pH; ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003epH Calibration\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eautomatic 0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eprobe condition indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003epH Sensor Check\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003emV Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e±825mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003emV Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e1mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003emV Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e±1mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eEC Range\u003c\/td\u003e\n\u003ctd style=\"width: 37.7263%; text-align: center;\"\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003ctd style=\"width: 37.1275%; text-align: center;\"\u003e\n\u003cbr\u003e0.00 to 20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eEC Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 37.7263%; text-align: center;\"\u003e1 µS\/cm\u003c\/td\u003e\n\u003ctd style=\"width: 37.1275%; text-align: center;\"\u003e0.01 mS\/cm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 37.7263%; text-align: center;\"\u003e±2% F.S.\u003c\/td\u003e\n\u003ctd style=\"width: 37.1275%; text-align: center;\"\u003e±2% F.S.\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eEC Calibration\u003c\/td\u003e\n\u003ctd style=\"width: 37.7263%; text-align: center;\"\u003eautomatic, one-point at 1413µS\/cm\u003c\/td\u003e\n\u003ctd style=\"width: 37.1275%; text-align: center;\"\u003eautomatic, one-point at 12.88mS\/cm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eTDS Range\u003c\/td\u003e\n\u003ctd style=\"width: 37.7263%; text-align: center;\"\u003e0 to 2000ppm (mg\/L)\u003c\/td\u003e\n\u003ctd style=\"width: 37.1275%; text-align: center;\"\u003e0.00 to 10.00 ppt (g\/L)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 37.7263%; text-align: center;\"\u003e1ppm (mg\/L)\u003c\/td\u003e\n\u003ctd style=\"width: 37.1275%; text-align: center;\"\u003e0.01 ppt (g\/L)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 37.7263%; text-align: center;\"\u003e±2% F.S.\u003c\/td\u003e\n\u003ctd style=\"width: 37.1275%; text-align: center;\"\u003e±2% F.S.\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eβ selectable from 0.0 to 2.4 %\/°C with 0.1 increment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eselectable from 0.45 to 1.00 with 0.01 increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e‐5.0 to 105.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003epH\/EC Probe\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eHI12883 PVC body, pre-amplified multiparameter probe with internal temperature sensor, quick connect DIN connector and 1m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003euser selectable: after 8 min, 60 min or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e1.5V (3) AAA \/ approximately 600 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eIP Protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e0 to 50°C; RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e154 x 63 x 30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6637%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 74.7104%; text-align: center;\"\u003e196g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Low range EC \/ Each","offer_id":42664155283646,"sku":"EHI991300","price":1146.0,"currency_code":"AUD","in_stock":true},{"title":"High range EC \/ Each","offer_id":42664155316414,"sku":"EHI991301","price":1146.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EHI991300-P.jpg?v=1769578348"},{"product_id":"ph-ec-do-multiparameter-meter-portable","title":"HI98194 multiparameter water quality waterproof meter, 12 parameters","description":"\u003cp\u003eThe HI98194 is a waterproof portable logging multiparameter meter that monitors up to 12 different water quality parameters including 6 measured and 6 calculated. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged. The HI98194 is supplied with all necessary accessories and packaged in a durable carrying case.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e12 Parameter Dot Matrix Display\u003c\/li\u003e\n\u003cli\u003eMulti-sensor Probe\u003c\/li\u003e\n\u003cli\u003eQuick Calibration\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 22.5054%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 76.3363%; text-align: center;\"\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eRange\u003c\/th\u003e\n\u003ctd data-th=\"pH Range\" style=\"width: 76.3363%; text-align: center;\"\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"pH Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd data-th=\"pH Accuracy\" style=\"width: 76.3363%; text-align: center;\"\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd data-th=\"pH Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 22.5054%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 76.3363%; text-align: center;\"\u003e\u003cstrong\u003eORP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eRange\u003c\/th\u003e\n\u003ctd data-th=\"ORP Range\" style=\"width: 76.3363%; text-align: center;\"\u003e±2000.0mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"ORP Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003e0.1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd data-th=\"ORP Accuracy\" style=\"width: 76.3363%; text-align: center;\"\u003e±1.0mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd data-th=\"ORP Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 22.5054%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 76.3363%; text-align: center;\"\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eRange\u003c\/th\u003e\n\u003ctd data-th=\"mV Range\" style=\"width: 76.3363%; text-align: center;\"\u003e±600.0mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"mV Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003e0.1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd data-th=\"mV Accuracy\" style=\"width: 76.3363%; text-align: center;\"\u003e±0.5mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 22.5054%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 76.3363%; text-align: center;\"\u003e\u003cstrong\u003eEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eRange\u003c\/th\u003e\n\u003ctd data-th=\"EC Range\" style=\"width: 76.3363%; text-align: center;\"\u003e0 to 200mS\/cm (absolute EC up to 400mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"EC Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003eauto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd data-th=\"EC Accuracy\" style=\"width: 76.3363%; text-align: center;\"\u003e±1% of reading or ±1 µS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd data-th=\"EC Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic single point, with six standard solutions (84µS\/cm, 1413µS\/cm, 5.00mS\/cm, 12.88mS\/cm, 80.0mS\/cm, 111.8mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 22.5054%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 76.3363%; text-align: center;\"\u003e\u003cstrong\u003eTDS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eRange\u003c\/th\u003e\n\u003ctd data-th=\"TDS Range\" style=\"width: 76.3363%; text-align: center;\"\u003e0 to 400000 ppm (mg\/L); (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"TDS Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003emanual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd data-th=\"TDS Accuracy\" style=\"width: 76.3363%; text-align: center;\"\u003e±1% of reading or ±1ppm (mg\/L), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd data-th=\"TDS Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 22.5054%; background-color: rgb(239, 239, 239);\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.3363%; background-color: rgb(239, 239, 239); text-align: center;\"\u003e\u003cstrong\u003eSalinity (PSU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003e Range\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Range\" style=\"width: 76.3363%; text-align: center;\"\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003e Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003e Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Accuracy\" style=\"width: 76.3363%; text-align: center;\"\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003e Calibration\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 22.5054%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 76.3363%; text-align: center;\"\u003e\u003cstrong\u003eSalinity (Seawater Sigma)\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003e Range\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (Seawater Sigma) Range\" style=\"width: 76.3363%; text-align: center;\"\u003e0.0 to 50.0 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (Seawater Sigma) Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003e0.1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (Seawater Sigma) Accuracy\" style=\"width: 76.3363%; text-align: center;\"\u003e±1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (Seawater Sigma) Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 22.5054%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 76.3363%; text-align: center;\"\u003e\n\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eRange\u003c\/th\u003e\n\u003ctd data-th=\"Resistivity Range\" style=\"width: 76.3363%; text-align: center;\"\u003e0 to 999999Ω-cm; 0 to 1000.0kΩ-cm; 0 to 1.0000MΩ-cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"Resistivity Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003edependent on resistivity reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd data-th=\"Resistivity Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 22.5054%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); width: 76.3363%; text-align: center;\"\u003e\u003cstrong\u003eDissolved Oxygen\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003e Measurement Type\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Measurement Type\" style=\"width: 76.3363%; text-align: center;\"\u003ePolarographic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003e Range\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Range\" style=\"width: 76.3363%; text-align: center;\"\u003e0.0 to 500.0%; 0.00 to 50.00ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003e0.1%; 0.01ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Accuracy \" style=\"width: 76.3363%; text-align: center;\"\u003e0.0 to 300.0% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic one or two points at 0 and 100% or one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eTemperature Compensation\u003c\/th\u003e\n\u003ctd data-th=\"Dissolved Oxygen Temperature Compensation\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic from 0.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eBarometric Pressure Compensation\u003c\/th\u003e\n\u003ctd data-th=\"Barometric Pressure Compensation\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic from 450 to 850mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eSalinity Compensation\u003c\/th\u003e\n\u003ctd data-th=\"Salinity Compensation\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic from 0 to 70g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239);\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); text-align: center;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003e0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Accuracy\" style=\"width: 76.3363%; text-align: center;\"\u003e±0.15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCompensation\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Compensation\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic from -5 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239);\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); text-align: center;\"\u003e\u003cstrong\u003eGeneral Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eLogging Memory\u003c\/th\u003e\n\u003ctd data-th=\"Logging Memory\" style=\"width: 76.3363%; text-align: center;\"\u003e45,000 records (continuous logging or log-on-demand of all parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eLogging Interval\u003c\/th\u003e\n\u003ctd data-th=\"Logging Interval\" style=\"width: 76.3363%; text-align: center;\"\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd data-th=\"Connectivity\" style=\"width: 76.3363%; text-align: center;\"\u003eUSB to PC with HI9298194 Hanna software installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd data-th=\"Battery Type\/Life\" style=\"width: 76.3363%; text-align: center;\"\u003e1.5V AA batteries (4) \/ approximately 360 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd data-th=\"Environment\" style=\"width: 76.3363%; text-align: center;\"\u003e0 to 50°C; RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" style=\"width: 76.3363%; text-align: center;\"\u003e185 x 93 x 35.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eWeight\u003c\/th\u003e\n\u003ctd data-th=\"Weight\" style=\"width: 76.3363%; text-align: center;\"\u003e400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eIncludes\u003c\/th\u003e\n\u003ctd data-th=\"Ordering Information\" style=\"width: 76.3363%; text-align: center;\"\u003eHI98194 is supplied with HI7698194 probe, HI7698194-1 pH\/ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239);\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: rgb(239, 239, 239); text-align: center;\"\u003e\u003cstrong\u003eAtmospheric Pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003e Range\u003c\/th\u003e\n\u003ctd data-th=\"Atmospheric Pressure Range\" style=\"width: 76.3363%; text-align: center;\"\u003e60.00 to 113.32kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eResolution\u003c\/th\u003e\n\u003ctd data-th=\"Atmospheric Pressure Resolution\" style=\"width: 76.3363%; text-align: center;\"\u003e0.01kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd data-th=\"Atmospheric Pressure Accuracy\" style=\"width: 76.3363%; text-align: center;\"\u003e±3mm Hg within ±15% from calibration point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 22.5054%;\"\u003eCalibration\u003c\/th\u003e\n\u003ctd data-th=\"Atmospheric Pressure Calibration\" style=\"width: 76.3363%; text-align: center;\"\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664257093822,"sku":"HI98194","price":2995.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI98194.png?v=1757390152"},{"product_id":"edge-dedicated-conductivity-tds-salinity-meter","title":"Hanna Edge dedicated EC\/TDS\/salinity meter","description":"\u003cp\u003eHanna Instruments is proud to introduce the world's most innovative Conductivity\/TDS\/Salinity meter: edge.\u003c\/p\u003e\u003cp\u003eedge's groundbreaking design is the culmination of Hanna's vision, design capabilities, integrated production and world-class R\u0026amp;D. edge is a single meter that can measure \u003cstrong\u003eConductivity, TDS and Salinity\u003c\/strong\u003e and is incredibly easy to use.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFour ring conductivity Probe: \u003c\/strong\u003eEdge EC\/TDS\/Salinity utilises four ring conductivity probe technology that allows the user to measure samples from very low conductivity to very high conductivity. edge is an auto-ranging meter that will select the appropriate range for the measurement to ensure the highest accuracy available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCapacitive Touch: \u003c\/strong\u003eEdge features a capacitive touch keypad that gives a distinctive, modern look. The keypad is sensitive enough to be used with laboratory gloves and has a fast response. Since the keypad is part of the screen, there are no buttons to get clogged with sample residue.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLarge Easy to Read LCD: \u003c\/strong\u003eEdge features a 5.5\" LCD display that you can clearly view from over 5 meters away. The large display and its wide 150° viewing angle provide one of the easiest to read LCD's in the industry.\u003c\/p\u003e\u003cp\u003e\u003ca class=\"btn\" href=\"https:\/\/proscitech.freshdesk.com\/en\/support\/solutions\/articles\/44002527316-hanna-edge%C2%AE\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd data-th=\"Product Name\" style=\"width: 72.4014%; text-align: center;\"\u003eedge dedicated EC, 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eEC Range\u003c\/th\u003e\n\u003ctd data-th=\"EC Range\" style=\"width: 72.4014%; text-align: center;\"\u003e0.00 to 29.99µS\/cm, 30.0 to 299.9µS\/cm, 300 to 2999µS\/cm, 3.00 to 29.99mS\/cm, 30.0 to 200.0mS\/cm, up to 500.0mS\/cm (absolute EC)**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eEC Resolution\u003c\/th\u003e\n\u003ctd data-th=\"EC Resolution\" style=\"width: 72.4014%; text-align: center;\"\u003e0.01µS\/cm, 0.1µS\/cm, 1µS\/cm, 0.01mS\/cm, 0.1mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eEC Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"EC Accuracy\" style=\"width: 72.4014%; text-align: center;\"\u003e±1% of reading (±0.05µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eEC Calibration\u003c\/th\u003e\n\u003ctd data-th=\"EC Calibration\" style=\"width: 72.4014%; text-align: center;\"\u003e1 point offset calibration (0.00µS\/cm in air), 1 point slope calibration in EC standard 84µS\/cm, 1413µS\/cm, 5.00mS\/cm, 12.88mS\/cm, 80.0 mS\/cm and 111.8mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eTDS Range\u003c\/th\u003e\n\u003ctd data-th=\"TDS Range\" style=\"width: 72.4014%; text-align: center;\"\u003e0.00 to 14.99ppm (mg\/L), 15.0 to 149.9ppm (mg\/L), 150 to 1499ppm (mg\/L), 1.50 to 14.99g\/L, 15.0 to 100.0g\/L, up to 400.0g\/L (absolute TDS)**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eTDS Resolution\u003c\/th\u003e\n\u003ctd data-th=\"TDS Resolution\" style=\"width: 72.4014%; text-align: center;\"\u003e0.01ppm, 0.1ppm, 1ppm, 0.01g\/L, 0.1g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eTDS Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"TDS Accuracy\" style=\"width: 72.4014%; text-align: center;\"\u003e±1% of reading (±0.03ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eTDS Calibration\u003c\/th\u003e\n\u003ctd data-th=\"TDS Calibration\" style=\"width: 72.4014%; text-align: center;\"\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eEC\/TDS Temperature Compensation\u003c\/th\u003e\n\u003ctd data-th=\"EC\/TDS Temperature Compensation\" style=\"width: 72.4014%; text-align: center;\"\u003eAutomatic -5 to 100° C; NoTC - none absolute conductivity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eTemperature Correction Coefficient\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Correction Coefficient\" style=\"width: 72.4014%; text-align: center;\"\u003e0.00 to 6.00% \/°C (for EC and TDS only). Default value is 1.90% \/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eEC to TDS Conversion Factor\u003c\/th\u003e\n\u003ctd data-th=\"EC to TDS Conversion Factor\" style=\"width: 72.4014%; text-align: center;\"\u003e0.40 to 0.80 (default value is 0.50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity (% NaCl) Range\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (% NaCl) Range\" style=\"width: 72.4014%; text-align: center;\"\u003e0.0 to 400.0% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity (% NaCl) Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (% NaCl) Resolution\" style=\"width: 72.4014%; text-align: center;\"\u003e0.1% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity (% NaCl) Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (% NaCl) Accuracy\" style=\"width: 72.4014%; text-align: center;\"\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity (% NaCl) Calibration\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (% NaCl) Calibration\" style=\"width: 72.4014%; text-align: center;\"\u003eSingle point with HI 7037L Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity (PSU) Range\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Range\" style=\"width: 72.4014%; text-align: center;\"\u003e2.00 to 42.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity (PSU) Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Resolution\" style=\"width: 72.4014%; text-align: center;\"\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity (PSU) Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Salinity (PSU) Accuracy\" style=\"width: 72.4014%; text-align: center;\"\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity Range\u003c\/th\u003e\n\u003ctd data-th=\"Salinity Range\" style=\"width: 72.4014%; text-align: center;\"\u003e0.0 to 80.0g\/L*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity Resolution (ppt)\u003c\/th\u003e\n\u003ctd data-th=\"Salinity Resolution (ppt)\" style=\"width: 72.4014%; text-align: center;\"\u003e0.01g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eSalinity Accuracy (ppt)\u003c\/th\u003e\n\u003ctd data-th=\"Salinity Accuracy (ppt)\" style=\"width: 72.4014%; text-align: center;\"\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eTemperature Range\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Range\" style=\"width: 72.4014%; text-align: center;\"\u003e-20.0 to 120.0°C**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eTemperature Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Resolution\" style=\"width: 72.4014%; text-align: center;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Accuracy\" style=\"width: 72.4014%; text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eEC\/TDS Probe\u003c\/th\u003e\n\u003ctd data-th=\"EC\/TDS Probe\" style=\"width: 72.4014%; text-align: center;\"\u003eHI763100 EC\/temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eLogging Type\u003c\/th\u003e\n\u003ctd data-th=\"Logging Type\" style=\"width: 72.4014%; text-align: center;\"\u003eManual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs\/lot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eLogging Memory\u003c\/th\u003e\n\u003ctd data-th=\"Logging Memory\" style=\"width: 72.4014%; text-align: center;\"\u003eUp to 1000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd data-th=\"Connectivity\" style=\"width: 72.4014%; text-align: center;\"\u003e1 micro USB port for charging and PC connectivity, 1 USB port for storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eGLP\u003c\/th\u003e\n\u003ctd data-th=\"GLP\" style=\"width: 72.4014%; text-align: center;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd data-th=\"Battery Type\/Life\" style=\"width: 72.4014%; text-align: center;\"\u003eBuilt-in rechargeable battery with up to 8 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd data-th=\"Power Supply\" style=\"width: 72.4014%; text-align: center;\"\u003e5 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd data-th=\"Environment\" style=\"width: 72.4014%; text-align: center;\"\u003e0 to 50°C, RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" style=\"width: 72.4014%; text-align: center;\"\u003e202 x 140 x 12.7mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eWeight\u003c\/th\u003e\n\u003ctd data-th=\"Weight\" style=\"width: 72.4014%; text-align: center;\"\u003e250g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 26.4403%;\"\u003eOrdering Information\u003c\/th\u003e\n\u003ctd data-th=\"Ordering Information\" style=\"width: 72.4014%; text-align: center;\"\u003eedgeEC HI2003 includes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664904982718,"sku":"HI2003-02","price":1425.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI2003-02.jpg?v=1767316157"},{"product_id":"orp-test-solution-240mv","title":"ORP test solution, 240mV","description":"\u003cp\u003eHI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePrepared with reagent grade chemicals\u003c\/li\u003e\n\u003cli\u003eAllows for a quick check of your ORP electrode\u003c\/li\u003e\n\u003cli\u003eAir tight bottle with tamper-proof seal to ensure quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664920285374,"sku":"HANHI7021L","price":75.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI7021La.jpg?v=1757382313"},{"product_id":"water-quality-test-kit","title":"Water quality test kit","description":"\u003cp\u003eWater quality test kit; alkalinity (as CaCO3), chloride (as Chlorine-), hardness as (CaCO3), iron, pH, and sulphite (as Na2SO3)\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664938209470,"sku":"HAN3817","price":685.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HAN3817.png?v=1757382316"},{"product_id":"groline-waterproof-portable-ph-ec-tds-meter","title":"GroLine portable pH\/EC\/TDS meter, waterproof","description":"\u003cp\u003eThe HI9814 is a slim, lightweight, waterproof, portable meter that measures  the pH, conductivity (EC), total dissolved solids (TDS), and temperature of nutrient solutions used in hydroponics, aquaponics and greenhouse growing. The meter has two-button operation, one for turning the meter on\/off and calibration while the other switches between the measurement modes. The HI9814 has advanced features including a selectable EC to TDS conversion factor (0.5 - 500ppm and 0.7 - 700ppm).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e3 in 1 amplified probe with pH, EC\/TDS and temperature sensors\u003c\/li\u003e\n\u003cli\u003eQuick Cal Mode to calibrate pH and EC\/TDS with one solution\u003c\/li\u003e\n\u003cli\u003eEC to TDS Conversion factor selectable between 0.5 (500 ppm) and 0.7 (700 ppm)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd data-th=\"Product Name\" style=\"width: 64.1741%; text-align: center;\"\u003eGroline Hydroponic Waterproof pH\/EC\/TDS\/Temperature Portable Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003epH Range\u003c\/th\u003e\n\u003ctd data-th=\"pH Range\" style=\"width: 64.1741%; text-align: center;\"\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003epH Resolution\u003c\/th\u003e\n\u003ctd data-th=\"pH Resolution\" style=\"width: 64.1741%; text-align: center;\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003epH Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"pH Accuracy\" style=\"width: 64.1741%; text-align: center;\"\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003epH Calibration\u003c\/th\u003e\n\u003ctd data-th=\"pH Calibration\" style=\"width: 64.1741%; text-align: center;\"\u003eautomatic, at one or two points using standard buffers (pH 4.01, 7.01,10.01); one point calibration using quick calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003epH Temperature Compensation\u003c\/th\u003e\n\u003ctd data-th=\"pH Temperature Compensation\" style=\"width: 64.1741%; text-align: center;\"\u003eautomatic ‐5.0 to 105.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003epH CAL Check (electrode diagnostics)\u003c\/th\u003e\n\u003ctd data-th=\"pH CAL Check (electrode diagnostics)\" style=\"width: 64.1741%; text-align: center;\"\u003eprobe condition indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003epH Sensor Check\u003c\/th\u003e\n\u003ctd data-th=\"pH Sensor Check\" style=\"width: 64.1741%; text-align: center;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003emV Range\u003c\/th\u003e\n\u003ctd data-th=\"mV Range\" style=\"width: 64.1741%; text-align: center;\"\u003e±825mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003emV Resolution\u003c\/th\u003e\n\u003ctd data-th=\"mV Resolution\" style=\"width: 64.1741%; text-align: center;\"\u003e1mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003emV Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"mV Accuracy\" style=\"width: 64.1741%; text-align: center;\"\u003e±1mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eEC Range\u003c\/th\u003e\n\u003ctd data-th=\"EC Range\" style=\"width: 64.1741%; text-align: center;\"\u003e0.00 to 6.00mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eEC Resolution\u003c\/th\u003e\n\u003ctd data-th=\"EC Resolution\" style=\"width: 64.1741%; text-align: center;\"\u003e0.01mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eEC Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"EC Accuracy\" style=\"width: 64.1741%; text-align: center;\"\u003e±2% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eEC Calibration\u003c\/th\u003e\n\u003ctd data-th=\"EC Calibration\" style=\"width: 64.1741%; text-align: center;\"\u003eautomatic, one-point at 1.41 mS\/cm; one-point calibration using quick calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eTDS Range\u003c\/th\u003e\n\u003ctd data-th=\"TDS Range\" style=\"width: 64.1741%; text-align: center;\"\u003e0 to 3000ppm (500 CF); 0 to 3990ppm (700 CF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eTDS Resolution\u003c\/th\u003e\n\u003ctd data-th=\"TDS Resolution\" style=\"width: 64.1741%; text-align: center;\"\u003e10 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eTDS Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"TDS Accuracy\" style=\"width: 64.1741%; text-align: center;\"\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eEC\/TDS Temperature Compensation\u003c\/th\u003e\n\u003ctd data-th=\"EC\/TDS Temperature Compensation\" style=\"width: 64.1741%; text-align: center;\"\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eTemperature Correction Coefficient\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Correction Coefficient\" style=\"width: 64.1741%; text-align: center;\"\u003eβ = 1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eEC to TDS Conversion Factor\u003c\/th\u003e\n\u003ctd data-th=\"EC to TDS Conversion Factor\" style=\"width: 64.1741%; text-align: center;\"\u003e0.5 (500 ppm) or 0.7 (700 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eTemperature Range\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Range\" style=\"width: 64.1741%; text-align: center;\"\u003e‐5.0 to 105.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eTemperature Resolution\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Resolution\" style=\"width: 64.1741%; text-align: center;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"Temperature Accuracy\" style=\"width: 64.1741%; text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003epH\/EC Probe\u003c\/th\u003e\n\u003ctd data-th=\"pH\/EC Probe\" style=\"width: 64.1741%; text-align: center;\"\u003eHI1285-7 pH\/conductivity probe with built-in temperature sensor, quick connect DIN connector and 1m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eAutomatic Shut-Off\u003c\/th\u003e\n\u003ctd data-th=\"Automatic Shut-Off\" style=\"width: 64.1741%; text-align: center;\"\u003euser selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd data-th=\"Battery Type\/Life\" style=\"width: 64.1741%; text-align: center;\"\u003e1.5V (3) AAA \/ approximately 600 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eIP Protection\u003c\/th\u003e\n\u003ctd data-th=\"IP Protection\" style=\"width: 64.1741%; text-align: center;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd data-th=\"Environment\" style=\"width: 64.1741%; text-align: center;\"\u003e0 to 50°C, RH max. 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" style=\"width: 64.1741%; text-align: center;\"\u003e154 x 63 x 30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 34.6676%;\"\u003eWeight\u003c\/th\u003e\n\u003ctd data-th=\"Weight\" style=\"width: 64.1741%; text-align: center;\"\u003e196g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42665118826686,"sku":"HI9814","price":529.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI9814-Single-Meter.jpg?v=1757382318"},{"product_id":"halo-wireless-soil-ph-meter","title":"HALO wireless soil pH meter","description":"\u003cp\u003eOur HALO Wireless Soil pH Meter has a triple ceramic junction in the outer reference cell, built-in temperature sensor, and the conic pH sensing tip making it ideal for pH measurements in soil samples. All readings are transmitted directly to your Apple or Android device or the edge blu.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTake laboratory grade pH and temperature measurements using your smart phone or tablet.\u003c\/li\u003e\n\u003cli\u003eEasily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology.\u003c\/li\u003e\n\u003cli\u003eGroup your data by time or notation. Email it for storage or share it with friends or colleagues.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe HALO Wireless Soil pH Meter incorporates Bluetooth Smart technology with an application-specific design. There are several features that make it ideal for measuring the pH of soil.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cimg\u003eLow Temperature Glass Formulation\u003c\/strong\u003e for fast stabilisation and more accurate results at lower temperatures.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cimg\u003eTriple Ceramic Junction\u003c\/strong\u003e allows a higher flow rate of electrolyte from the reference cell into the measurement sample. The increased flow provides greater continuity between the reference electrode and the indicating electrode.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cimg\u003eConical Glass Tip\u003c\/strong\u003e design allows for penetration into solids, semi-solids, and emulsions. The HI12922 is ideal for the direct measurement of pH in soil and soil slurries.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReal-Time Data \u003c\/strong\u003edisplay of pH and temperature updated every second. Readings are automatically saved to a history file every hour, limited only by the available memory on the device.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e Fluid, Dynamic Graphing m\u003c\/strong\u003eeasurements can be displayed alone on the display, with tabulated data, or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e GLP (Good Laboratory Practice) \u003c\/strong\u003edisplays date and time of current calibration, offset, and average slope, along with calibrated buffers, mV values, temperature and slopes between each buffer.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cimg\u003eCalibration Reminder \u0026amp; Measurement Alarms\u003c\/strong\u003e alerts you when HALO needs calibration or if a measurement threshold is exceeded.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cimg\u003eLog \u0026amp; Share Data \u003c\/strong\u003esaved log files may be annotated with measurement-specific information. Data is easily shared via email in CSV format.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cimg\u003eHelp \u0026amp; Tutorials\u003c\/strong\u003e with demo mode helps you explore features of the Hanna Lab App. General app information, HALO information, pH tutorial, maintenance tutorial, and contact information are available in help.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eBody Material\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003eglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eReference\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003edouble, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eJunction \/ Flow Rate\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003eceramic, triple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eElectrolyte\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003e3.5M KCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eRange\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003epH: 0 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eTip Shape\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003econic (12 x 12mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eDiameter\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003e12mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eBody Length \/ Overall Length\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003e120mm \/ 195mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eRecommended Operating Temperature\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003e-5°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003e0.0°C to 50.0°C, electronic module is not waterproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eTemperature Sensor\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003eintegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eAmplifier\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eDigital\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003eBluetooth Smart (Bluetooth 4.0), 10m range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003eCR2032 3V lithium ion \/ approximately 500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eApplications\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003eagriculture, direct soil pH measurement, hydroponics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eOrdering Information\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003eHI12922 (HALO) is supplied with auger, storage solution, cleaning solution, pH 7.01 buffer solution, pH 4.01 buffer solution, fill solution, battery, quality certificate, and instruction sheet. Smartphone and tablet not included.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 34.6842%;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"width: 64.1575%; text-align: center;\"\u003e6 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eHanna Lab App Measurement Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e-2.000 to 16.000 pH \/ ±800mV \/ -20.0 to 120.0C *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.1, 0.01, 0.001 pH \/ 1, 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy (@25 deg C\/77 deg F)\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.005 pH \/ ±0.3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCalibration Points\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eUp to five points with seven standard buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCalibration Buffers\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Compensation\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eAutomatic from -5.0°C to 100.0°C* (will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility\/System Requirements\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eAndroid: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later.\u003cbr\u003eiOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDownload Information\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eHanna Lab App is available free from the Play Store or App Store\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42665119088830,"sku":"HI12922","price":562.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/wireless-ph-meter-for-soil-halo-side-view-hi12922.jpg?v=1757382320"},{"product_id":"foodcare-meat-ph-tester","title":"Foodcare meat pH tester","description":"\u003cp\u003eDesigned to bring simplicity to pH testing of soil, the HI981036 Meat pH Tester is engineered to withstand the tough environment of meat processing plants. The built-in probe features an open reference junction, conical glass tip, and a removable sleeve design making it ideal for measuring the pH of soil.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e±0.2 pH accuracy\u003c\/li\u003e\n\u003cli\u003eComes with all the necessary solutions and batteries- everything you need to get started measuring right away.\u003c\/li\u003e\n\u003cli\u003eSpecialised electrode for spot checking the pH during meat processing.\u003c\/li\u003e\n\u003cli\u003eOnscreen stability indicator with selectable auto-off feature prolongs battery life. \u003c\/li\u003e\n\u003cli\u003eCompact size makes the Meat pH Tester ideal for on-the-go testing with  large LCD display and single button operation streamlines the testing process for any user.\u003c\/li\u003e\n\u003cli\u003eIncluded CR2032 Li-ion battery provides up to 1000 hours of continuous use. The battery icon will blink on low battery.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eYour measurements require detailed attention; so should your electrode. The HI981036 Meat pH Tester features a built-in probe that has been carefully designed for taking direct pH measurements during meat processing. \u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncluded CR2032 Li-ion battery provides up to 1000 hours of continuous use. The battery icon will blink on low battery.\u003c\/li\u003e\n\u003cli\u003eSimple to remove the sleeve for quick cleaning and new electrolyte. Having a clean probe with a fresh reference electrolyte will improve performance and extend the life of the tester. \u003c\/li\u003e\n\u003cli\u003eConical shaped tip design allows for direct penetration into meat and meat products.\u003c\/li\u003e\n\u003cli\u003ePolyvinylidene fluoride (PVDF) body is a durable plastic that is resistant to most chemicals and solvents used for disinfection in the food sector, including chlorine (bleach).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eMeat pH Tester is equipped with everything you need for successful testing right out of the box and comes with cleaning solution that has been engineered to keep your electrode free from oils and protiens found in meat and meat products. This concentrated combination of detergents cleans your tester quickly and effectively so that your tester stays in optimum condition. \u003c\/p\u003e\u003cp\u003eWhen performing a pH calibration it is important that the correct buffers are used. We include some start buffers to get you going. The single-use sachets are individually sealed so you use fresh buffer each time you calibrate.  \u003c\/p\u003e\u003cp\u003eProper storage of your electrode will ensure reliable measurements and a long electrode life. Our storage solution is specially formulated to keep the pH glass hydrated while minimising organic growth.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cdd\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 29.7888%;\"\u003epH Range\u003c\/th\u003e\n\u003ctd style=\"width: 68.956%;\"\u003e0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 29.7888%;\"\u003epH Resolution\u003c\/th\u003e\n\u003ctd style=\"width: 68.956%;\"\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 29.7888%;\"\u003epH Accuracy\u003c\/th\u003e\n\u003ctd style=\"width: 68.956%;\"\u003e±0.2 pH @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 29.7888%;\"\u003epH Calibration\u003c\/th\u003e\n\u003ctd style=\"width: 68.956%;\"\u003eAutomatic, at one or two points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 29.7888%;\"\u003epH Temperature Compensation\u003c\/th\u003e\n\u003ctd style=\"width: 68.956%;\"\u003enone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 30.3282%;\"\u003eAutomatic Shut-Off\u003c\/th\u003e\n\u003ctd style=\"width: 68.4166%;\"\u003e8 minutes, 60 minutes, or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 30.3282%;\"\u003eBattery Type \/ Life\u003c\/th\u003e\n\u003ctd style=\"width: 68.4166%;\"\u003eCR2032 Li-ion \/ Approximately 1000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 30.3282%;\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd style=\"width: 68.4166%;\"\u003e0 to 50°C; RH 95% max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 30.3282%;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 68.4166%;\"\u003e51 x 151 x 21mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 30.3282%;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.4166%;\"\u003e44g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 30.3282%;\"\u003eOrdering Information\u003c\/th\u003e\n\u003ctd style=\"width: 68.4166%;\"\u003eEach HI981036 Meat pH Tester is supplied with: - pH 4.01 buffer solution liquid sachet (2 pcs.) - pH 7.01 buffer solution liquid sachet (2 pcs.) - Meat, grease and fats acid cleaning solution (2 pcs.) - Electrode storage solution, 13 mL dropper - Electrode fill solution - Instruction manual - Quality certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 30.3282%;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"width: 68.4166%;\"\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/dd\u003e\u003cdd\u003e\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\u003c\/dd\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42665119252670,"sku":"HI981036","price":289.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI981036-Meat-pH-Tester.png?v=1757382324"},{"product_id":"marine-salinity-tester","title":"Marine salinity tester","description":"\u003cp\u003eDesigned to bring simplicity to salinity testing during the any process, the HI98319 Marine Salinity Tester measures conductivity (EC) to determine the salinity of natural and artificial seawater. Within seconds, the salinity and temperature are digitally displayed on the LCD. Tester comes with a complimentary carrying case to keep your tester safe from potential drops or bumps when not in use. \u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDisplays results in parts per thousand (ppt), Practical Salinity Units (PSU), or specific gravity (S.G.).\u003c\/li\u003e\n\u003cli\u003eComes with all the necessary solutions and batteries- everything you need to get started measuring right away.\u003c\/li\u003e\n\u003cli\u003eIdeal for testing salinity in aquariums, field, and industrial settings.\u003c\/li\u003e\n\u003cli\u003eOnscreen stability indicator for highest level of confidence in your results.\u003c\/li\u003e\n\u003cli\u003eThe selectable auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.\u003c\/li\u003e\n\u003cli\u003eCompact size ideal for on-the-go testing with multilevel LCD display and dual button operation.\u003c\/li\u003e\n\u003cli\u003eCR2032 Li-ion battery included, provides up to 100 hours of continuous use, battery icon will blink on low battery.\u003c\/li\u003e\n\u003cli\u003eGraphite sensors reduces polarisation effects and does not oxidise for more reliable and accurate readings.\u003c\/li\u003e\n\u003cli\u003eDesigned to withstand the knocks, drops, and spills of real life, the waterproof body ensures meters are totally protected against dust and water intrusion from any direction. \u003c\/li\u003e\n\u003cli\u003eExposed temperature sensor to ensure fast, accurately compensated readings even during sudden temperature fluctuations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNOTE: When performing a calibration it is important that the correct buffers are used. We include some starter buffer to get you going. The single-use sachets are individually sealed so you use fresh buffer each time you calibrate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCR2032 battery (inside the meter)\u003c\/li\u003e\n\u003cli\u003eStorage \/ Protection sleeve\u003c\/li\u003e\n\u003cli\u003eInstruction manual, Quality certificate\u003c\/li\u003e\n\u003cli\u003e35.00ppt calibration standard sachet (4 pcs.)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e-10°C to +300°C (HI99551-00); -20.0 to 199.9°C (HI99551-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eHI147-00 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.2°C (-20 to 50°C), ±0.3°C (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Resolution\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCalibration\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003emanual, one point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Compensation\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eautomatic from 0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd style=\"text-align: center;\"\u003eCR2032 Li-ion approximately 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e68g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42665120235710,"sku":"HI98319","price":215.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI98319-Angle-ppt-F.jpg?v=1757382327"},{"product_id":"ammonia-high-range-checker-hc","title":"Ammonia high range checker HC","description":"\u003cp\u003eThe Hanna Ammonia High-Range (0 to 99.9 ppm) Checker bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in color. Professional instrumentation incorporates a light source such as an LED or tungsten lamp with a filter and a light sensing detector to precisely determine ion concentration. Professional instrumentation offers greater resolution and accuracy but can cost hundreds of dollars. The Hanna Ammonia High Range Checker uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCompact, Portable Design\u003c\/li\u003e\n\u003cli\u003eBuilt-in Timer\u003c\/li\u003e\n\u003cli\u003eOne-Button Operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAmmonia Range\u003c\/th\u003e\n\u003ctd\u003e0.0 to 99.9 ppm as NH4+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmmonia Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmmonia Accuracy\u003c\/th\u003e\n\u003ctd\u003e±1.0 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmmonia Method\u003c\/th\u003e\n\u003ctd\u003eadaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eGeneral Meter:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic Shut-Off\u003c\/th\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50°C; RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e64g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhotometer\/Colorimeter Light Source\u003c\/th\u003e\n\u003ctd\u003eLED @ 470nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhotometer\/Colorimeter Light Detector\u003c\/th\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrdering Information\u003c\/th\u003e\n\u003ctd\u003eHI733 Checker is supplied with (2) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI733A-0 and 1 bottle of HI733B-0), battery, instructions and quick start guide.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42665120432318,"sku":"HI733","price":125.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI733-checkerhc-front.jpg?v=1757382330"},{"product_id":"ammonia-low-range-checker-hc","title":"Ammonia low range checker HC","description":"\u003cp\u003eThe Hanna Ammonia Low-Range Checker bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in colour. Professional instrumentation incorporates a light source such as an LED or tungsten lamp with a filter and a light sensing detector to precisely determine absorbance and ion concentration. Professional instrumentation offers greater resolution and accuracy but can cost hundreds of dollars. The Hanna Ammonia Low-Range Checker uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCompact, Portable Design\u003c\/li\u003e\n\u003cli\u003eBuilt-in Timer\u003c\/li\u003e\n\u003cli\u003eOne-Button Operation\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAmmonia Range\u003c\/th\u003e\n\u003ctd\u003e0.00 to 3.00 ppm NH3-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmmonia Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmmonia Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.05 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmmonia Method\u003c\/th\u003e\n\u003ctd\u003eadaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic Shut-Off\u003c\/th\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50°C; RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e64g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhotometer\/Colorimeter Light Source\u003c\/th\u003e\n\u003ctd\u003eLED @ 470nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhotometer\/Colorimeter Light Detector\u003c\/th\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrdering Information\u003c\/th\u003e\n\u003ctd\u003eHI700 Checker is supplied with (2) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI700A-0 reagent A and 1 bottle of HI700B-0 reagent B), battery, instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42665120628926,"sku":"HI700","price":143.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI700-checkerhc-front_1.jpg?v=1757382332"},{"product_id":"checker-plus-ph-tester","title":"Checker plus pH tester, 0.01 pH resolution","description":"\u003cp\u003eThe EHI98100 Checker Plus pH tester has been designed. The Checker Plus has a pentagon design with a 103mm long probe tapered to a 8mm diameter, making it ideal for test tubes and vials.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eEconomical\u003c\/strong\u003e - The Checker Plus is a full-featured pH tester at an affordable price.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLarge LCD\u003c\/strong\u003e - Enhanced LCD that displays reading, stability indicator, low battery indicator and calibration tags.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplaceable pH Electrode\u003c\/strong\u003e - The HI1271 supplied gel filled pH electrode tapers to an 8mm diameter at the sensing end. This narrow electrode easily fits into test tubes, vials, and other containers with small opening.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAutomatic Calibration\u003c\/strong\u003e - The Checker Plus is calibrated automatically to one or two points. The calibration buffers are automatically recognized and after calibration the buffer values used are shown on the display as a tag.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eStability Indicator\u003c\/strong\u003e - An hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilized the indicator disappears and a reading can be recorded.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAutomatic Shut-Off\u003c\/strong\u003e - The meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life. The auto off feature can be disabled.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLong Battery Life\u003c\/strong\u003e - The Checker Plus has an exceptionally long battery life of approximately 1000 hours. When the battery power is running low a low battery indicator is displayed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd data-th=\"Product Name\" style=\"width: 70.3532%; text-align: center;\"\u003eChecker Plus pH Tester with 0.01 pH resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003epH Range\u003c\/th\u003e\n\u003ctd data-th=\"pH Range\" style=\"width: 70.3532%; text-align: center;\"\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003epH Resolution\u003c\/th\u003e\n\u003ctd data-th=\"pH Resolution\" style=\"width: 70.3532%; text-align: center;\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003epH Accuracy\u003c\/th\u003e\n\u003ctd data-th=\"pH Accuracy\" style=\"width: 70.3532%; text-align: center;\"\u003e±0.2 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003epH Calibration\u003c\/th\u003e\n\u003ctd data-th=\"pH Calibration\" style=\"width: 70.3532%; text-align: center;\"\u003eautomatic, one or two points with three standard buffers available (pH 4.01, 7.01 and 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003epH Electrode\u003c\/th\u003e\n\u003ctd data-th=\"pH Electrode\" style=\"width: 70.3532%; text-align: center;\"\u003eHI1271 pH electrode with screw type connector (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003eAutomatic Shut-Off\u003c\/th\u003e\n\u003ctd data-th=\"Automatic Shut-Off\" style=\"width: 70.3532%; text-align: center;\"\u003e8 minutes, 60 minutes, or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003eBattery Type\/Life\u003c\/th\u003e\n\u003ctd data-th=\"Battery Type\/Life\" style=\"width: 70.3532%; text-align: center;\"\u003e1.5V CR2032 (1) \/ approximately 1000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003eEnvironment\u003c\/th\u003e\n\u003ctd data-th=\"Environment\" style=\"width: 70.3532%; text-align: center;\"\u003e0 to 50°C; RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" style=\"width: 70.3532%; text-align: center;\"\u003e50 x 174 x 21mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width: 28.4885%;\"\u003eWeight\u003c\/th\u003e\n\u003ctd data-th=\"Weight\" style=\"width: 70.3532%; text-align: center;\"\u003e50g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42665126265022,"sku":"EHI98100","price":129.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI98100.jpg?v=1780546706"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/collections\/HannaInstruments.png?v=1773896044","url":"https:\/\/proscitech.com.au\/collections\/hanna-instruments.oembed?page=2","provider":"ProSciTech","version":"1.0","type":"link"}