{"title":"Hanna - Solutions","description":"","products":[{"product_id":"ph-calibration-buffer-ph6-86-500ml","title":"Electrode calibration solution, pH 6.86","description":"\u003cp\u003eHI7006L is a premium quality pH 6.86 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAir tight bottle with tamper-proof seal to ensure quality and freshness of solution\u003c\/li\u003e\n\u003cli\u003eEach bottle marked with lot number and expiration date. Hanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\n\u003cli\u003eColour coded label for easy pH buffer value identification for different buffer values\u003c\/li\u003e\n\u003cli\u003eSolution does not contain any dyes that may stain the reference cell of a pH electrode\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"margin-right: calc(0%); width: 100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003eDescription\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003estandard calibration buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003eCertificate of Analysis\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003epH Accuracy\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003epH Value @ 25°C\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003e6.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 33.9693%;\"\u003ePackage\u003c\/th\u003e\n\u003ctd style=\"text-align: center; width: 64.8724%;\"\u003ebottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664107114686,"sku":"HI7006L","price":45.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI7006.jpg?v=1767318027"},{"product_id":"standard-calibration-solution-9-18-ph-500ml","title":"Electrode calibration solution, pH 9.18","description":"\u003cp\u003eHI7009L is a premium quality pH 9.18 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664107311294,"sku":"HI7009L","price":45.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/hi7009l__1.jpg?v=1757382211"},{"product_id":"electrode-storage-solution-1","title":"Hanna electrode storage solution","description":"\u003cp\u003eA storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionised water. The Hanna Instruments storage solution is specifically formulated to minimise microbial growth and to prevent any effects of diffusion\/osmotic from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and\/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300L storage solution for at least one hour before taking measurements.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSpecial formulation to minimise microbial growth and osmotic\/diffusion effects between the solution and inner reference electrolyte\u003c\/li\u003e\n\u003cli\u003eManufactured specifically for pH and ORP electrodes\u003c\/li\u003e\n\u003cli\u003eClearly marked expiration date and lot number\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"30ml","offer_id":43291058503870,"sku":"HI70300S","price":33.0,"currency_code":"AUD","in_stock":true},{"title":"500ml","offer_id":42664107507902,"sku":"HI70300L","price":53.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI70300.jpg?v=1780546448"},{"product_id":"zero-oxygen-solution-500ml","title":"Zero oxygen solution","description":"\u003cp\u003eHI7040L is a high quality, bicomponent zero oxygen solution made from reagent grade chemicals. Hanna dissolved oxygen solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.  Prepared with reagent grade chemicals. Hassle-free, easy to mix chemical component bottles.  Air-tight seal to ensure the quality of the solution. \u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664107540670,"sku":"HI7040L","price":66.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI7040L.jpg?v=1757382215"},{"product_id":"electrode-cleaning-solution-general-purpose","title":"Electrode cleaning solution","description":"\u003cp\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardisation curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60mV. The deviation from 0mV is not unusual but ideally should be no greater than ±30mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.\u003c\/p\u003e\u003cp\u003e \u003cimg title=\"cleaning solution\" src=\"https:\/\/hannainst.com.au\/media\/wysiwyg\/products\/solutions\/Screen_Shot_2015-01-08_at_3.20.38_PM.png\" alt=\"\"\u003eCleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI7061L cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.  \u003c\/p\u003e\u003cp dir=\"ltr\"\u003eAir tight bottle with tamper-proof seal\u003c\/p\u003e\u003cul\u003e\u003cli dir=\"ltr\"\u003e\u003cp dir=\"ltr\"\u003eEnsures quality and freshness of solution\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp dir=\"ltr\"\u003eEach bottle marked with lot number and expiration date.\u003c\/p\u003e\u003cul\u003e\u003cli dir=\"ltr\"\u003e\u003cp dir=\"ltr\"\u003eHanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664107573438,"sku":"HI7061L","price":45.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI7061L.jpg?v=1780546450"},{"product_id":"orp-test-solution-240mv","title":"ORP test solution, 240mV","description":"\u003cp\u003eHI7021L is a quality ORP test solution made from reagent grade chemicals and used to test platinum and gold ORP electrodes. Hanna test solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePrepared with reagent grade chemicals\u003c\/li\u003e\n\u003cli\u003eAllows for a quick check of your ORP electrode\u003c\/li\u003e\n\u003cli\u003eAir tight bottle with tamper-proof seal to ensure quality\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"500ml","offer_id":42664920285374,"sku":"HANHI7021L","price":75.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI7021La.jpg?v=1757382313"},{"product_id":"water-quality-test-kit","title":"Water quality test kit","description":"\u003cp\u003eWater quality test kit; alkalinity (as CaCO3), chloride (as Chlorine-), hardness as (CaCO3), iron, pH, and sulphite (as Na2SO3)\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":42664938209470,"sku":"HAN3817","price":685.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HAN3817.png?v=1757382316"},{"product_id":"ph-indicator-testing-phenol-red","title":"Phenol red pH indicator solution","description":"\u003cp\u003eThe HI93710-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Phenol Red method in which the reagents produce a range of color that is pH-dependent. By simply adding 5 drops from the bottle of reagent to the sample, the reaction between the sample and reagent causes a tint in the sample that varies from yellow to red. The intensity of colour is determined by a compatible photometer and the concentration will be displayed. The results will be displayed in pH units with a resolution of 0.1 pH. These reagents are designed to be used with samples that have an expected range of 6.5 to 8.5 pH.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePre-made reagents for ease of use\u003c\/li\u003e\n\u003cli\u003ePrepared with high-purity chemicals\u003c\/li\u003e\n\u003cli\u003eMarked with expiration date and lot number for traceability\u003c\/li\u003e\n\u003cli\u003ePhenol red method. The reaction with reagents causes a red tint in the sample\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Each","offer_id":43596749013182,"sku":"HI93710-01","price":60.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI93710-01.jpg?v=1757382382"},{"product_id":"chlorine-and-reagent-testing-kit","title":"Chlorine reagent testing kit, \u003c5mg\/L free chlorine","description":"\u003cp\u003eThe HI93701-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the DPD Method in which the reaction between chlorine and reagent causes a pink tint in the sample. The intensity of colour is determined by a compatible photometer and the concentration will be displayed. The results will be display the concentration of chlorine in mg\/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00mg\/L free chlorine.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePre-made reagents for ease of use\u003c\/li\u003e\n\u003cli\u003ePrepared with high-purity chemicals\u003c\/li\u003e\n\u003cli\u003eMarked with expiration date and lot number for traceability\u003c\/li\u003e\n\u003cli\u003eAdaptation of the USEPA method 330.5 and Standard Method 4500-Cl G\u003c\/li\u003e\n\u003cli\u003eThe reaction between chlorine and the reagents causes a pink tint in the sample\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Pack\/100","offer_id":43596749045950,"sku":"HI93701-01","price":75.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI93701-01.jpg?v=1757382385"},{"product_id":"chlorine-reagent-testing-kit-5mg-l-total-chlorine","title":"Chlorine reagent testing kit, \u003c5mg\/L total chlorine","description":"\u003cp\u003eThe HI93711-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the DPD Method in which the reaction between chlorine and reagent causes a pink tint in the sample. The intensity of color is determined by a compatible photometer and the total chlorine concentration will be displayed in mg\/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00mg\/L total chlorine.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePre-made reagents for ease of use\u003c\/li\u003e\n\u003cli\u003ePrepared with high-purity chemicals\u003c\/li\u003e\n\u003cli\u003eMarked with expiration date and lot number for traceability\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Pack\/100","offer_id":43599334310078,"sku":"HI93711-01","price":75.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI93711-01.jpg?v=1757382391"},{"product_id":"ultra-high-range-chlorine-reagent-testing-kit","title":"Ultra high range chlorine reagent testing kit","description":"\u003cp\u003eThe HI95771-01 are reagents for the colorimetric determination of chlorine in the ultra high range. There are enough reagents for 100 tests to be used with Hanna’s HI96771 portable photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePre-dosed reagents for ease of use\u003c\/li\u003e\n\u003cli\u003eSupplied with certificate of quality\u003c\/li\u003e\n\u003cli\u003eMarked with expiration date and lot number for traceability\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/sds.hannainst.com\/vi\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eHanna Instruments SDS Search\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Pack\/100","offer_id":43599334539454,"sku":"HI95771-01","price":82.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/HI95771-01.jpg?v=1757382393"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/collections\/HannaLogoBlue-2x-2.png?v=1767314345","url":"https:\/\/proscitech.com.au\/collections\/hanna-solutions.oembed","provider":"ProSciTech","version":"1.0","type":"link"}