{"title":"Hawach - PVDF Syringe Filters","description":null,"products":[{"product_id":"syringe-filter-non-sterile-hydrophobic-pvdf","title":"PVDF syringe filters, hydrophobic, non-sterile","description":"\u003cp\u003eHydrophobic Polyvinylidene fluoride membranes are suitable for use with a wide range of applications from filtering of biological samples to clarify mild organic HPLC solutions. Provides fast flow rates and is generally compatible with most common solvents. Exhibits very low protein binding, make it ideal for protein recovery applications. Offers low extractables and broad chemical compatibility. It have very similar application with hydrophobic PTFE, also used with aggressive solvents, strong acids, alcohols, bases and aromatics. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHigh flow rate and low protein binding \u003c\/li\u003e\n\u003cli\u003eStandard 1um pre-filter providing increased sample handling capacity \u003c\/li\u003e\n\u003cli\u003eAble to filter solutions at temperatures up to +60C \u003c\/li\u003e\n\u003cli\u003eAutoclave at 121°C at 1 bar for 20 minutes\/EO\/Gamma \u003c\/li\u003e\n\u003cli\u003eIdeal for HPLC sample preparation and removal of protein precipitates\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHawach syringe filters are designed with medical grade polypropylene shell and high-quality membranes, made to ISO9001 standard, CE double approved, COA test report available. \u003c\/p\u003e\u003cp\u003e\u003ca class=\"btn\" href=\"https:\/\/support.proscitech.com.au\/article\/1\" rel=\"noopener noreferrer\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eFilter Media\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003ePolyvinylidene fluoride\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eDiameter\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e4mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e13mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e25mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e33mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e50mm\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eHousing\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003eMedical PP\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePore Size\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eFiltration Area\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e0.2cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e1.3cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e4.9cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e8.5cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e19.8cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eMaximum Pressure\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eProcess Volume\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e2ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e10ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e100ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e200ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5000ml\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePre-filter\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e1μm GF or PP\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eHold-up Volume\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 10μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 50μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 100μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 200μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 350μl\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eInlet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e\u003cp\u003eFemale Luer Lock\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003eStepped barb\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eOutlet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e\u003cp\u003eMale Luer slip\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003eStepped barb\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eOperation Temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e60°C\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hawach","offers":[{"title":"25mm \/ 0.22um \/ Pack\/100","offer_id":42664242217150,"sku":"WS7-02225N","price":135.0,"currency_code":"AUD","in_stock":true},{"title":"50mm \/ 0.45um \/ Pack\/25","offer_id":42664242249918,"sku":"WS7-04550N","price":363.0,"currency_code":"AUD","in_stock":true},{"title":"25mm \/ 1.00um \/ Pack\/100","offer_id":42664242282686,"sku":"WS7-10025N","price":150.0,"currency_code":"AUD","in_stock":true},{"title":"25mm \/ 5.00um \/ Pack\/100","offer_id":42664242315454,"sku":"WS7-50025N","price":150.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/WS7-PVDF.jpg?v=1763942016"},{"product_id":"syringe-filter-non-sterile-pvdf-gf-prefilter","title":"PVDF syringe filters, GF prefilter, non-sterile","description":"\u003cp\u003eHydrophobic Polyvinylidene fluoride membranes are suitable for use with a wide range of applications from filtering of biological samples to clarify mild organic HPLC solutions. Provides fast flow rates and is generally compatible with most common solvents. Exhibits very low protein binding, make it ideal for protein recovery applications. Offers low extractables and broad chemical compatibility. It have very similar application with hydrophobic PTFE, also used with aggressive solvents, strong acids, alcohols, bases and aromatics. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHigh flow rate and low protein binding \u003c\/li\u003e\n\u003cli\u003eStandard 1um pre-filter providing increased sample handling capacity \u003c\/li\u003e\n\u003cli\u003eAble to filter solutions at temperatures up to +60C \u003c\/li\u003e\n\u003cli\u003eAutoclave at 121°C at 1 bar for 20 minutes\/EO\/Gamma \u003c\/li\u003e\n\u003cli\u003eIdeal for HPLC sample preparation and removal of protein precipitates\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHawach syringe filters are designed with medical grade polypropylene shell and high-quality membranes, made to ISO9001 standard, CE double approved, COA test report available. \u003c\/p\u003e\u003cp\u003e\u003ca class=\"btn\" href=\"https:\/\/support.proscitech.com.au\/article\/1\" rel=\"noopener noreferrer\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eFilter Media\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003ePolyvinylidene fluoride\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eDiameter\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e4mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e13mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e25mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e33mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e50mm\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eHousing\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003eMedical PP\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePore Size\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eFiltration Area\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e0.2cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e1.3cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e4.9cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e8.5cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e19.8cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eMaximum Pressure\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eProcess Volume\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e2ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e10ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e100ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e200ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5000ml\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePre-filter\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e1μm GF or PP\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eHold-up Volume\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 10μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 50μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 100μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 200μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 350μl\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eInlet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e\u003cp\u003eFemale Luer Lock\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003eStepped barb\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eOutlet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e\u003cp\u003eMale Luer slip\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003eStepped barb\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eOperation Temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e60°C\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ctable style=\"margin-right: calc(8%); width: 92%;\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hawach","offers":[{"title":"25mm \/ 0.22um \/ Pack\/100","offer_id":42664242512062,"sku":"WS7-02225NG","price":176.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/WS7-PVDF_e9974e4f-ec4a-41e3-8230-a80047b7dd8b.jpg?v=1763942017"},{"product_id":"syringe-filter-non-sterile-pvdf-pp-prefilter","title":"PVDF syringe filters, hydrophobic, PP prefilter, non-sterile","description":"\u003cp\u003eHydrophobic Polyvinylidene fluoride membranes are suitable for use with a wide range of applications from filtering of biological samples to clarify mild organic HPLC solutions. Provides fast flow rates and is generally compatible with most common solvents. Exhibits very low protein binding, make it ideal for protein recovery applications. Offers low extractables and broad chemical compatibility. It have very similar application with hydrophobic PTFE, also used with aggressive solvents, strong acids, alcohols, bases and aromatics. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHigh flow rate and low protein binding \u003c\/li\u003e\n\u003cli\u003eStandard 1um pre-filter providing increased sample handling capacity \u003c\/li\u003e\n\u003cli\u003eAble to filter solutions at temperatures up to +60C \u003c\/li\u003e\n\u003cli\u003eAutoclave at 121°C at 1 bar for 20 minutes\/EO\/Gamma \u003c\/li\u003e\n\u003cli\u003eIdeal for HPLC sample preparation and removal of protein precipitates\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHawach syringe filters are designed with medical grade polypropylene shell and high-quality membranes, made to ISO9001 standard, CE double approved, COA test report available. \u003c\/p\u003e\u003cp\u003e\u003ca class=\"btn\" href=\"https:\/\/support.proscitech.com.au\/article\/1\" rel=\"noopener noreferrer\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eFilter Media\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003ePolyvinylidene fluoride\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eDiameter\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e4mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e13mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e25mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e33mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e50mm\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eHousing\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003eMedical PP\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePore Size\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eFiltration Area\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e0.2cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e1.3cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e4.9cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e8.5cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e19.8cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eMaximum Pressure\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eProcess Volume\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e2ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e10ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e100ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e200ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5000ml\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePre-filter\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e1μm GF or PP\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eHold-up Volume\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 10μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 50μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 100μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 200μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 350μl\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eInlet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e\u003cp\u003eFemale Luer Lock\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003eStepped barb\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eOutlet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e\u003cp\u003eMale Luer slip\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003eStepped barb\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eOperation Temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e60°C\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hawach","offers":[{"title":"13mm \/ 0.22um \/ Pack\/100","offer_id":42664242610366,"sku":"WS7-02213NP","price":126.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/WS7-PVDF_4330c7e8-3292-47b3-87f5-0dc3c761125a.jpg?v=1763942019"},{"product_id":"syringe-filter-sterile-pvdf","title":"PVDF syringe filters, hydrophobic, sterile","description":"\u003cp\u003eHydrophobic Polyvinylidene fluoride membranes are suitable for use with a wide range of applications from filtering of biological samples to clarify mild organic HPLC solutions. Provides fast flow rates and is generally compatible with most common solvents. Exhibits very low protein binding, make it ideal for protein recovery applications. Offers low extractables and broad chemical compatibility. It have very similar application with hydrophobic PTFE, also used with aggressive solvents, strong acids, alcohols, bases and aromatics. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHigh flow rate and low protein binding \u003c\/li\u003e\n\u003cli\u003eGamma-ray sterilised nylon syringe filter is individually packaged\u003c\/li\u003e\n\u003cli\u003eStandard 1um pre-filter providing increased sample handling capacity \u003c\/li\u003e\n\u003cli\u003eAble to filter solutions at temperatures up to +60C \u003c\/li\u003e\n\u003cli\u003eAutoclave at +121C at 1 bar for 20 minutes\/EO\/Gamma \u003c\/li\u003e\n\u003cli\u003eIdeal for HPLC sample preparation and removal of protein precipitates\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHawach syringe filters are designed with medical grade polypropylene shell and high-quality membranes, made to ISO9001 standard, CE double approved, COA test report available. \u003c\/p\u003e\u003cp\u003e\u003ca class=\"btn\" href=\"https:\/\/support.proscitech.com.au\/article\/1\" rel=\"noopener noreferrer\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eFilter Media\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003ePolyvinylidene fluoride\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eDiameter\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e4mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e13mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e25mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e33mm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e50mm\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eHousing\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003eMedical PP\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePore Size\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm, 10μm\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eFiltration Area\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e0.2cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e1.3cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e4.9cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e8.5cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e19.8cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eMaximum Pressure\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5.2bar\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eProcess Volume\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e2ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e10ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e100ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e200ml\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e5000ml\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePre-filter\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e1μm GF or PP\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eHold-up Volume\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 10μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 50μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 100μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 200μl\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e\u0026lt; 350μl\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eInlet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e\u003cp\u003eFemale Luer Lock\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003eStepped barb\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eOutlet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e\u003cp\u003eMale Luer slip\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003e6:100 Luer slip\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eFlow Direction\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e\u003cp\u003eFlow should enter from the inlet\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cp\u003eBoth is fine\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eOperation Temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e60°C\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eSterilisation\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003eGamma Irradiation\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eEndotoxin\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003e\u003cp\u003e≦0.25 EU\/ML\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hawach","offers":[{"title":"13mm \/ 0.22um \/ Pack\/100","offer_id":42664245690558,"sku":"WS7-02213S","price":159.0,"currency_code":"AUD","in_stock":true},{"title":"13mm \/ 0.45um \/ Pack\/100","offer_id":42664245723326,"sku":"WS7-04513S","price":159.0,"currency_code":"AUD","in_stock":true},{"title":"33mm \/ 0.45um \/ Pack\/50","offer_id":42664245756094,"sku":"WS7-04533S","price":174.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/WS7-PVDF_894e5f49-cb52-479d-b95d-027125dc7c58.jpg?v=1763942032"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/collections\/WS3-PES_f0142db2-ef96-4ba4-87fa-b70c5e1d2f62.jpg?v=1784856170","url":"https:\/\/proscitech.com.au\/collections\/hawach-pvdf-syringe-filters.oembed","provider":"ProSciTech","version":"1.0","type":"link"}