{"product_id":"pelco-easiglow-cryo-em-glow-discharge-system-and-accessories","title":"PELCO easiGlow cryo-em glow discharge system and accessories","description":"\u003cp\u003eThe PELCO easiGlow Glow Discharge Cleaning System is a compact, quick and easy to use standalone system. It is primarily designed for cleaning TEM grids and hydrophilisation of TEM carbon support films, which have the tendency to be hydrophobic. A glow discharge treatment with air will make a carbon film surface negatively charged (hydrophilic) which allows aqueous solutions to spread easily.\u003cbr\u003e\u003cbr\u003eGlow discharge treatment of TEM grids removes adsorbed hydrocarbons, cleaning them while making them hydrophilic. The PELCO easiGlow is an affordable and easy to operate glow discharge system for any TEM lab.\u003cbr\u003e\u003cbr\u003eThe practical chamber size with its newly designed glow discharge head and adjustable stage with glass slide holder allows for easy loading and fast turnaround times. The system is fully microprocessor controlled and includes an intelligent touch screen device for control and display of operation parameters. The PELCO easiGlow supports both hydrophilic and hydrophobic treatment with either negative or positive charge and includes two separately controlled gas inlets. The required vacuum level is set by an electronically controlled precision proportional valve. This novel approach eliminates manual setting with a needle valve. A gentle venting procedure ensures that the TEM grids are not disturbed when the system is vented.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGlow Discharge Methods Supported1\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width: 20.3125%;\"\u003eSurface Condition\u003c\/th\u003e\n\u003cth style=\"width: 21.5794%; text-align: center;\"\u003eCharge\u003c\/th\u003e\n\u003cth style=\"width: 57.5305%; text-align: center;\"\u003eAtmosphere\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.3125%;\"\u003eHydrophilic\u003c\/td\u003e\n\u003ctd style=\"width: 21.5794%; text-align: center;\"\u003eNegative\u003c\/td\u003e\n\u003ctd style=\"width: 57.5305%; text-align: center;\"\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.3125%;\"\u003eHydrophilic\u003c\/td\u003e\n\u003ctd style=\"width: 21.5794%; text-align: center;\"\u003ePositive\u003c\/td\u003e\n\u003ctd style=\"width: 57.5305%; text-align: center;\"\u003eAir (with subsequent magnesium Acetate treatment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.3125%;\"\u003eHydrophobic\u003c\/td\u003e\n\u003ctd style=\"width: 21.5794%; text-align: center;\"\u003ePositive\u003c\/td\u003e\n\u003ctd style=\"width: 57.5305%; text-align: center;\"\u003eAmylamine (Pentylamine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20.3125%;\"\u003eHydrophobic\u003c\/td\u003e\n\u003ctd style=\"width: 21.5794%; text-align: center;\"\u003eNegative\u003c\/td\u003e\n\u003ctd style=\"width: 57.5305%; text-align: center;\"\u003eMethanol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOptimised for cleaning TEM grids\u003c\/li\u003e\n\u003cli\u003ePrecise and easy vacuum setting\u003c\/li\u003e\n\u003cli\u003eShort cycle times\u003c\/li\u003e\n\u003cli\u003eConsistent results\u003c\/li\u003e\n\u003cli\u003eAuto, programmed and manual mode\u003c\/li\u003e\n\u003cli\u003eIntuitive touch screen for display and operation\u003c\/li\u003e\n\u003cli\u003eSupports hydrophilic\/hydrophobic and negative\/positive modes\u003c\/li\u003e\n\u003cli\u003eAffordable, compact, standalone system\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca class=\"btn\" href=\"https:\/\/proscitech.freshdesk.com\/en\/support\/solutions\/articles\/44002527468-pelco-easiglow%E2%84%A2-glow-discharge-system\" rel=\"noopener noreferrer\" style=\" font-size: 16px; display: inline-block; width: 160px; text-align: center; padding: 10px; color: #000000; background-color: #fff; text-decoration: none; border-radius: 5px; box-shadow: 0px 4px 6px rgba(0, 0, 0, 0.2); background-image: linear-gradient(to bottom, #007bff; font-family: helvetica neue; transition: transform 0.1s ease;\" target=\"_blank\"\u003eTechnical Data\u003c\/a\u003e\u003c\/p\u003e\u003cdiv style=\"width: 640px; height: 360px; float: none; clear: both; margin: 2px auto;\"\u003e\u003cembed src=\"https:\/\/player.vimeo.com\/video\/601350913?autohide=1\u0026amp;autoplay=0\" type=\"video\/mp4\" width=\"100%\" height=\"100%\" allowfullscreen=\"\" title=\"Vimeo video player\"\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePELCO easiGlow single chamber system:\u003c\/strong\u003e Available without optional extras\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePELCO easiGlow dual chamber system:\u003c\/strong\u003e Ideal for regular use of hydrophilic and hydrophobic surface treatments, a dual glow discharge system is available to avoid cross contamination of the glow discharge chambers. Hydrophobic surfaces are preferable when organic solvents are used\u003c\/p\u003e\u003cp\u003e\u003ca name=\"91002\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePELCO easiGlow discharge set includes: \u003c\/strong\u003ePELCO easiGlow unit, Vacuum pump with all accessories, Rubber gasket to protect the glass chamber edge and PELCO Grid Holder Block\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eManufactured in USA\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlasma Current\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0-30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV Power supply\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e30W Continuous Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlow Discharge Head Polarity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eUser Selectable positive or negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Platform\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eØ75mm with recess for 25 x 75mm slide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlow Discharge Platform Height Control\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1-25mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreprocess Hold Timer\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0-14411 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Timer\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0-900 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Size\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eØ 120 x 100mm H with sealed Delrin top plate (inside Ø106 x 90mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess\/Vent gas inlets\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2 each Ø 6mm barbed, individually user selectable for process, purge or vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Voltage Vacuum Interlocks\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDual hardware and software interlocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Control\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003ePirani Gauge, ranging from atmosphere to 0.01mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Vacuum Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1.1 - 0.20mbar for optimal glow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Control \/ Display\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e3\" Touch Panel with LED backlight and 5 function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Modes\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eAuto Programmed (4 user programmed protocols) Manual\/Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Capabilities\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eStep #, Vacuum (mbar), Current (mA), Voltage (V), and polarity, once per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Size (L x D x W)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e305 x 292 x 230mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e6.26kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD4 Pump (optional) (L x D x H)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e337 x 138 x 244mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e11kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory Footprint with optional pump (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e381 x 292 x 330mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e230V 50Hz, 10A Service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Power Rating\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e240VAC, 50Hz 60W Plus Pump, IEC Inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Pump Power Rating\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e230V 50Hz 370 W (1\/2 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump Minimum requirements\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.03mbar Ultimate Vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump Power Outlet on Instrument\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e8A max IEC Outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Inlet\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eKF 16 flange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging Capabilities\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eStep #, Vacuum (mbar), Current (mA), Voltage (V), and polarity, once per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eUSB Outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eOptional accessories and replacement parts:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width: 23.7452%;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"width: 114.093%;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEL16820-25, PEL16820-81\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/proscitech.com.au\/products\/pelco-easiglow-tem-grid-holder-blocks\" rel=\"noopener noreferrer\" target=\"_blank\"\u003ePELCO easiGlow TEM grid holder blocks\u003c\/a\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETP91040-230\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/proscitech.com.au\/products\/gd4-vacuum-pumping-system-connection-kits-for-glow-discharge\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eGD4 vacuum pumping system connection kits for glow discharge\u003c\/a\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.7452%;\"\u003eETP91050\u003c\/td\u003e\n\u003ctd style=\"width: 114.093%;\"\u003eReplacement Glass Chamber with sealed top plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.7452%;\"\u003eETP91000-2\u003c\/td\u003e\n\u003ctd style=\"width: 114.093%;\"\u003eReplacement Touch Screen Stylus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.7452%;\"\u003eETP91051\u003c\/td\u003e\n\u003ctd style=\"width: 114.093%;\"\u003eO-ring for Glow Discharge Chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.7452%;\"\u003eETP91053\u003c\/td\u003e\n\u003ctd style=\"width: 114.093%;\"\u003eProtective L-gasket, use with O-ring for ETP91050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.7452%;\"\u003eETP91010-16\u003c\/td\u003e\n\u003ctd style=\"width: 114.093%;\"\u003ePELCO easiGlow Vacuum Connection Kit to KF16 Pump inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.7452%;\"\u003eETP91010-25\u003c\/td\u003e\n\u003ctd style=\"width: 114.093%;\"\u003ePELCO easiGlow Vacuum Connection Kit to KF25 Pump inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.7452%;\"\u003eETP91010-30\u003c\/td\u003e\n\u003ctd style=\"width: 114.093%;\"\u003eDual Vacuum Connection Kit for Dual Chamber Glow Discharge System to KF 16 pump inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.7452%;\"\u003eETP9609\u003c\/td\u003e\n\u003ctd style=\"width: 114.093%;\"\u003eExhaust filter for GD7 or #7010 Rotary Vacuum Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.7452%;\"\u003eETP891-35\u003c\/td\u003e\n\u003ctd style=\"width: 114.093%;\"\u003eUltragrade 19 Rotary Pump Oil for GD7, 1L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp data-empty=\"true\"\u003e1. Reference for glow discharge and use of amylamine to obtain Hydrophobic; positively charged surfaces: Hayat, M.A.2000. Principles and Techniques of Electron Microscopy Biological Applications, page 237-241. Cambridge University Press. ISBN 052163287\u003cbr\u003e\u003cbr\u003e2. Reference for glow discharge and use of subsequent Magnesium Acetate treatment to obtain Hydrophylic; charged surfaces: Portmann, R., and Koller, Th. 1976. The divalent cation method for protein-free spreading of nucleic acid molecules. In \u003cem\u003eProceedings of the 6th European Congress on Electron Microscopy\u003c\/em\u003e, Vol.2, p546.\u003c\/p\u003e","brand":"Ted Pella Inc (PELCO)","offers":[{"title":"Single easiGlow unit \/ Each","offer_id":48758914973886,"sku":"ETP91000-S","price":10265.0,"currency_code":"AUD","in_stock":true},{"title":"Dual easiGlow unit \/ Each","offer_id":48758915006654,"sku":"ETP91000-D","price":14792.0,"currency_code":"AUD","in_stock":true},{"title":"easiGlow set \/ Each","offer_id":48758915039422,"sku":"ETP91000SET","price":10357.0,"currency_code":"AUD","in_stock":true},{"title":"Glass chamber \/ Each","offer_id":48758915072190,"sku":"ETP91050","price":1215.0,"currency_code":"AUD","in_stock":true},{"title":"O-ring \/ Pack\/2","offer_id":48758915104958,"sku":"ETP91051","price":35.0,"currency_code":"AUD","in_stock":true},{"title":"L-gasket \/ Each","offer_id":48758915137726,"sku":"ETP91054","price":149.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/ETP91000-EG.png?v=1787115771","url":"https:\/\/proscitech.com.au\/products\/pelco-easiglow-cryo-em-glow-discharge-system-and-accessories","provider":"ProSciTech","version":"1.0","type":"link"}