{"product_id":"pfeiffer-duo-6-two-stage-rotary-vacuum-pump","title":"Pfeiffer DUO 6 two-stage rotary vacuum pump","description":"\u003cp\u003eThe Pfeiffer Duo 6 rotary vane pump has replaced the V3 and V5 Edwards pumps with a 5m\u003csup\u003e3\u003c\/sup\u003e\/h 2 stage oil sealed rotary vane pump by Quorum Technologies.\u003c\/p\u003e\u003cp\u003eAll sputter coaters require an appropriately sized, two stage mechanical pump. We recommend and supply Edwards (The British pump manufacturer) and Pfeiffer pumps (The German pump manufacturer). The Pfeiffer DUO 6 rotary pump is also the best size for SEM, TEM, evaporators and is very fast on sputter coaters, other preparation equipment and for the evacuation of refrigeration\/ air-conditioning systems. Within Australia and New Zealand we can supply these superior pumps very competitively. Turbo pumped instruments include the turbo pump, but require a mechanical pump.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eNote\u003c\/strong\u003e: A larger diaphragm pump is available in the Emitech range. However, it should be noted that larger diaphragm pumps, when compared with rotary pumps (also called mechanical pumps or fore-pumps) are a little noisier, require a little more maintenance, do not achieve as good an ultimate vacuum and are more expensive. The advantage of being totally oil-free remains and it is known that rotary pump oil can contaminate a system, streaming past the diffusion pump. The argument for a diaphragm pump backing of a turbo-molecular pump is weak, since that pump's action scarcely allows oil vapour into the pumped space. For small Diaphragm Vacuum Pumps, which provide a lesser vacuum, but are oil free and excellent for pumping \"wet\" materials.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cdiv id=\"listrow_4910_1\" style=\"background: transparent none repeat scroll 0% 0%;\"\u003eDual-stage, high-performance rotary vane pump with a pumping speed of 5m\u003csup\u003e3\u003c\/sup\u003e\/h\u003c\/div\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cdiv id=\"listrow_4910_2\" style=\"background: transparent none repeat scroll 0% 0%;\"\u003eWith Single-phase motor\u003c\/div\u003e\u003c\/li\u003e\n\u003cli\u003eIntegrated gas ballast and HV safety valve\u003c\/li\u003e\n\u003cli\u003eFor all low and medium vacuum applications\u003c\/li\u003e\n\u003cli\u003eMagnetically coupled\u003c\/li\u003e\n\u003cli\u003eSpecial feature: Various motor voltages for worldwide employment\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_0_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eEmission sound pressure level without gas ballast\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e≤ 57dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_1_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eExhaust pressure, max.\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e150hPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_2_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eExhaust pressure, min.\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e250hPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003eFlange (in)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003eDN 16 ISO-KF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_4_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eFlange (out)\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003eDN 16 ISO-KF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003eLeak rate safety valve\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e≤ 1x10\u003csup\u003e-4\u003c\/sup\u003e hPa L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_6_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eMagnetic coupling\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003eMains requirement: voltage @50Hz\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e200-240V (±5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_9_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eOperating fluid\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003eP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_10_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eOperating fluid filling\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e0.75L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003ePumping speed @50Hz\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e5m\u003csup\u003e3\u003c\/sup\u003e\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003eRated power @50Hz\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_13_1\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003e0.37kW\u003c\/div\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_15_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eRotation speed @50Hz\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_15_1\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003e1500rpm\u003c\/div\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_17_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eSwitch\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003eYes, with 2m mains cable and safety plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003eUltimate pressure with gas ballast\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e7 x 10\u003csup\u003e-3\u003c\/sup\u003e hPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_19_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eUltimate pressure without gas ballast\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e4 x 10\u003csup\u003e-3\u003c\/sup\u003e hPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 54.2472%;\"\u003e\u003cdiv class=\"edit_table_cell\" id=\"cell_7067_20_0\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eWeight\u003c\/div\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 44.5945%;\"\u003e25kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e240VAC 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv class=\"edit_text_block\" id=\"K13034_7068_6\" style=\"background: transparent none repeat scroll 0% 0%;\" title=\"Double click to edit\"\u003eUltimate pressure according to PNEUROP\u003c\/div\u003e","brand":"Pfeiffer Vacuum","offers":[{"title":"Each","offer_id":42664104296638,"sku":"EQT13034","price":3577.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1784\/2811\/files\/EQT13034.jpg?v=1768622009","url":"https:\/\/proscitech.com.au\/products\/pfeiffer-duo-6-two-stage-rotary-vacuum-pump","provider":"ProSciTech","version":"1.0","type":"link"}