MadgeTech temperature and pressure autoclave data loggers
MadgeTech temperature and pressure autoclave data loggers
The MadgeTech data loggers are rugged, high precision, temperature and humidity data loggers built for use in harsh environments. The stainless steel devices are submersible (IP68) and can withstand temperatures up to 140°C.
They can store up to 32,700 readings, and the EHiTemp140 features a rigid external probe capable of measuring extended temperatures, up to 260°C. The EPR140 has a pressure range from 0 to 5Bar and EPRTEMP140 has a temperature range of -20°C to +140°C. The devices record date and time stamped readings, and have non-volatile solid state memory which retains data even if the battery becomes discharged.
Using the MadgeTech 4 Software, starting, stopping and downloading the devices is simple and easy. To use, simply place the device in the IFC400 or IFC406 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K or °R. The data can also be automatically exported to Excel for further calculations.
Features:
- Operates up to 140°C
- Submersible (IP68)
- User Replaceable Battery
- Rugged Stainless Steel Body
- Programmable Stop/start Time
- Engraved Label
- CE Compliant
- Software Battery Life Indicator
- 0.125 inch NPT Pressure Port
- Interface dock, 6 port docking station and replacement battery available separately
Specifications:
| Model | EHITEMP140 |
EPR140 |
EPRTEMP140 |
| Pressure | |||
| Sensor | Semiconductor strain gauge | Strain gauge | |
| Range | 0 to 5Bar |
0 to 5Bar | |
| Resolution | 0.0001Bar |
0.0001Bar | |
| Accuracy | +0.03Bar +20 to +140°C |
+0.03Bar +20 to +140°C |
|
| Temperature | |||
|
Sensor |
100 Ω Platinum RTD |
Resistance Temperature Detector (RTD) |
|
|
Range |
-200°C to +260°C |
-20°C to +140°C |
|
|
Resolution |
0.01°C | 0.01°C | |
|
Accuracy |
±0.1°C (20 to +140°C) ±0.3°C (-20 to +20°C) ±0.4°C (-40 to -20°C) |
±0.1°C |
|
| General | |||
| Weight | 120g | Flush Top: 90g NPT Pressure Port Top:100g |
Flush Top: 90g NPT Pressure Port Top:100g |
| Dimensions | Body: 40mm x 24.6mm diameter Probe: 27mm x 3.2mm diameter up to 178mm x 4.8mm diameter |
Flush Top: 50.8mm x 25.4mm diameter NPT Pressure Port Top: 58.2mm x 25.4mm diameter |
Flush Top: 50.2mm x 24.6mm diameter NPT Pressure Port Top: 58.2mm x 24.6mm diameter |
| Material | 316 Stainless steel | ||
| Calibration | Digital via software, automatically recorded within device | ||
| Battery | 3.6V high temperature lithium, 2 year life | ||
| Data Format | Date and time stamped °C, K, °F or °R | PSIA, inHg, mmHg, bar, atm, Torr, Pa, kPa, MPa |
°C, °F, °R, K, bar, mbar, PSI, inHg, mmHg, atm, Torr, Pa, kPa, MPa |
| Time Accuracy | ±1min/month at 20°C to 30°C (stand alone mode) |
±1min/month at 25°C Extended Operation: ±20min/month at 140°C (±450ppm) |
|
| Computer Interface | IFC400 OR IFC406 USB docking station required; 125,000 baud |
IFC400 or IFC406 USB docking station required |
|
| OS Compatibility | Windows XP SP3 or later |
||
| Software Compatibility | Standard Software version 2.03.06 or laterSecure Software version 4.1.3.0 or later |
Standard Software version 2.06.02 or laterSecure Software version 4.1.3.0 or later |
Standard Software version 4.2.3.0 or laterSecure Software version 4.2.2.0 or later |
| Operating Environment | -40°C to +140°C 0%RH to 100%RH, 0.0001 to 7Bar |
-20°C to +140°C 0%RH to 100%RH, 0.0001 to 7Bar |
|
| IP Rating | IP68 | ||
| Approvals | CE | ||
PRTEMP140 product brochure PR140 product brochure
BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 150°C.